3.3V / 5V combined power limit is 170W maximum.
Table 38. DC/DC Converters Load Ratings
+12VDC Input DC/DC Converters
+3.3V Converter
+5V Converter
-12V Converter
Maximum Load
25.0A
30.0A
0.5A
Minimum Static / Dynamic Load
0.0A
0.0A
0.0A
Maximum Output Power, see table note
below
below
3.3x25=82.5W 5x30=150W 0.5x12=6W
Note:
The straight sum of the three maximum powers = 238.5W, but considering the 3.3/5V power limit, it may be 170W
+6W = 176W maximum combined power.
+6W = 176W maximum combined power.
5.3.3.12 Voltage
Regulation
The DC/DC converters’ output voltages must stay within the following voltage limits when
operating at steady state and dynamic loading conditions. These limits include the peak-peak
ripple/noise specified. All outputs are measured with reference to the return remote sense signal
(Returns). The 3.3V output is measured at the 3.3 RS point; all other voltages are measured at
the output harness connectors.
operating at steady state and dynamic loading conditions. These limits include the peak-peak
ripple/noise specified. All outputs are measured with reference to the return remote sense signal
(Returns). The 3.3V output is measured at the 3.3 RS point; all other voltages are measured at
the output harness connectors.
Table 39. Voltage Regulation Limits
Converter Output
Tolarance
Minimum
Nominal
Maximum
Units
+ 3.3VDC
- 5% / +5%
+3.14
+3.30
+3.46
VDC
+ 5VDC
- 5% / +5%
+4.75
+5.00
+5.25
VDC
+12VDC (12V1/2/3/4)
-5%/ +5%
+11.40
+12.00 +12.60 VDC
- 12VDC
- 5% / +9%
-11.40
-12.00
-13.08
VDC
5VSB
-5% / +5%
+4.75
+5.00
+5.25
VDC
5.3.3.13
Fan-less Operation in Stand-by Mode
The power supply will work indefinitely in standby mode with power on, power supply plus
power distribution board off, and the 5VSB at full load under environmental conditions
(temperature, humidity, altitude) as specified.
power distribution board off, and the 5VSB at full load under environmental conditions
(temperature, humidity, altitude) as specified.