Справочник Пользователя для Bosch DS794Z

Скачать
Страница из 4
Region
Certification
UL
ZX794Z: ANSR: Intrusion Detection
Units (UL639)
China
CCC
DS794ZE: 2007031901000035
Installation/configuration notes
24 m
0 m
0 m
8 m
8 m
80 ft
0 ft
0 ft
25 ft
25 ft
Top View
Standard Broad Coverage: 24 m x 16 m (80 ft x 50 ft)
0 ft
80 ft
0 ft
25 ft
0 m
24 m
0 m
8 m
Side View
Standard Broad Coverage: 24 m x 16 m (80 ft x 50 ft)
0 ft
5 ft
0 m
61 m
0 ft
200 ft
1.5 m
0 m
1.5 m
5 ft
Top View
Standard Long Range: 61 m x 3 m (200 ft x 10 ft)
0 ft
200 ft
0 ft
5 ft
61 m
0 m
1.5 m
0 m
Side View
Standard Long Range: 61 m x 3 m (200 ft x 10 ft)
0 m
0 m
37 m
3.8 m
3.8 m
120 ft
0 ft
0 ft
12.5 ft
12.5 ft
Top View
Optional Long Range 37 m x 8 m (120 ft x 26 ft)
0 m
0 m
37 m
0 ft
0 ft
7.5 ft
2.3 m
120 ft
Side View
Optional Long Range 37 m x 8 m (120 ft x 26 ft)
Standby Power
If there is no internal standby battery, connect to DC
power source capable of supplying standby power if
the primary power fails.
Model
Standby Power
mAh required per hour
DS794Z
No standby battery
18 mAh
DS794ZE
No standby battery
25 mAh
DS794ZE-FRA
No standby battery
18 mAh
ZX794Z
Provided by the
Zonex bus
0.5 mAh
Notice
A minimum of four hours of standby power is
required for UL Listed requirements.
Parts included
For your convenience, the OA200 Mirror and OA80
Mirror are included with the detector.
Technical specifications
Enclosure
Dimensions:
14 cm x 21 cm x 14 cm
(5 in. x 7.5 in. x 5 in.)
Material:
High impact ABS plastic enclosure
Environmental Considerations
Operating
Temperature:
-29°C to +49°C (-20°F to +120°F)
For UL Certificated installations, 0°C to +49°C
(+32°F to +120°F)
Radio
Frequency
Interference
(RFI) Immunity:
No alarm or setup on critical frequencies in the
range from 26 MHz to 950 MHz at 50 V/m.
DS794ZE:
Complies with Environmental Class II (EN50130-5)
Mounting
Height:
5 m (15 ft.) maximum
Location:
Surface or corner
Power Requirements
Current Draw:
18 mA at 12 VDC
25 mA at 12 VDC (DS794ZE)
Voltage (Input):
6 VDC to 15 VDC
ZX794Z: Power comes from two-wire Zonex Bus.
<0.5 mA nominal, 2 mA in alarm with LEDs
enabled. Do not leave Walk Test LEDs enabled.
2 | DS794Z and ZX794Z Series Long Range PIR Detectors