Справочник Пользователя для Bosch DS1102i DS1102I

Модели
DS1102I
Скачать
Страница из 3
Installation/configuration notes
Notice
Glassbreak detectors are intended only as a
component of a perimeter protection system.
They should always be used in conjunction with
motion sensors.
Mounting
Mount the DS1102i series detectors on the ceiling, or
on the wall opposite or adjacent to the window.
Coverage depends on room acoustics and window
size.
Standard Coverage
7.6 m (25 ft) for glass sizes over 30.5 cm x 30.5 cm
(12 in. x 12 in.).
Parts included
Quant.
Component
1
Detector
1
Hardware pack
1
Literature – Installation Guide
Technical specifications
Electrical
Current:
23 mA at 12 VDC
Voltage:
6 VDC to 15 VDC
Environmental
Operating
Temperature:
-29°C to +49°C (-20°F to +120°F)
For UL Certificated installations, 0°C to +49°C
(+32°F to +120°F)
Radio Frequency
Interference (RFI)
Immunity:
No alarm or setup on critical frequencies in the
range from 26 MHz to 950 MHz at 50 V/m.
Mechanical
Dimensions:
8.6 cm x 8.6 cm x 2.1 cm
(3.4 in. 3.4 in. x 0.83 in.)
Material:
High-impact ABS plastic enclosure
Outputs
Alarm:
Form C reed relay rated 3.5 W, 125 mA at
28 VDC for resistive loads.
Tamper:
Normally-closed (NC) cover‑activated tamper
switch with separate terminals. Contacts rated
at 28 VDC, 125  mA maximum.
Ordering information
DS1102i Glassbreak Detector
Order number 
DS1102i
DS1102i‑CHI Glassbreak Detector
Order number 
DS1102i‑CHI
Accessories
DS1110i Glassbreak Tester
Used to test DS1101i, DS1102i, DS1103i, and DS1108i
Glass Break Detectors. Powered by a 9 V alkaline
battery (supplied).
Order number 
DS1110i
 
2 | DS1102i Series Glassbreak Detectors