800.551.8948 | Fax 770.657.6807 |
Specifications
Conductor
Solid annealed copper
Insulation
Dual insulation consisting of an inner layer of foamed, natural
polyolefin over which is applied a solid (skin) layer of
polyolefin colored in accordance with industry standards
Twisted Pairs
Individual insulated conductors; twisted into pairs with
varying lay lengths; specific color combinations provide
pair identification
≤ 25-Pair Core
Pairs are assembled into a cylindrical core
> 25-Pair Core
Cables larger than 25-pair are assembled into units,
which are then used to assemble the core; units
are identifiable using color-coded binders
Filling Compound
80°C ETPR compound, completely filling the interstices
between the pairs and under the core wrap
Core Wrap
Non-hygroscopic, dielectric tape applied over the core
Shield
Corrugated, copolymer coated, 8 mil aluminum tape applied
longitudinally with an overlap; flooded shield interfaces
Jacket
Black, polyethylene
Jacket Marking
Identifying information includes a telephone handset,
cable code, pair count, AWG, date of manufacture
and sequential length markings at 2 foot intervals
Standards Compliance
ANSI/ICEA S-84-608-2007
RDUP 7 CFR 1755.890 (PE-89)
RoHS-compliant
Electrical Specifications
Number of Pairs
Average Mutual
Capacitance @ 1000 Hz
nF/mile (nF/km)
Capacitance Unbalance
Pair to Pair @ 1 kHz
Capacitance Unbalance
Pair to Ground @ 1 kHz
Maximum Individual
pF @ 1 kft (pF @ 1 km)
Maximum RMS
pF @ 1 kft (pF @ 1 km)
Maximum Individual
pF @ 1 kft (pF @ 1 km)
Maximum Average
pF @ 1 kft (pF @ 1 km)
12 or less
83 ± 7 (52 ± 4)
80 (145)
-
800 (2,625)
-
Over 12
83 ± 4 (52 ± 2)
80 (145)
25 (45)
800 (2,625)
175 (574)
Conductor Size
AWG (mm)
Minimum Insulation
Resistance @ 68°F (20°C)
gigohm-mile (gigohm-km)
Maximum Average
Attenuation*
772 kHz @ 68°F (20°C)
dB/kft (dB/km)
Maximum Conductor
Resistance @ 68°F (20°C)
Ohms/sheath
mile (km)
DC Resistance Unbalance
Maximum %
Dielectric Strength
DC Potential – Volts
Average
Individual
Pair
Conductor
to Conductor
Conductor
to Shield
19 (0.90)
1.0 (1.6)
3.2 (10.5)
45.0 (28.0)
1.5
5.0
4,500
10,000
22 (0.64)
1.0 (1.6)
4.5 (14.8)
91.0 (56.5)
1.5
5.0
3,600
10,000
24 (0.51)
1.0 (1.6)
5.6 (18.4)
144.0 (89.5)
1.5
5.0
3,000
10,000
26 (0.40)
1.0 (1.6)
7.0 (23.3)
232.0 (144.0)
1.5
5.0
2,400
10,000
*For cables with 12-pair or less, the maximum average attenuation may be increased by 10% over the values shown.
Minimum Near End Crosstalk (NEXT)
@ 772 kHz
PSWUNEXT Mean (dB)
47
PSWUNEXT Worst Pair (dB)
42
Minimum Far End Crosstalk (FEXT)
@ 772 kHz
Conductor Size (AWG)
19
22
24
26
PSELFEXT Mean (dB/kft)
51
49
49
47
PSELFEXT Worst Pair (dB/kft)
45
43
43
43
sealPiC®–FsF
RDUP PE-89
Product Description
SEALPIC®-FSF Cables are designed for low risk direct burial or duct
applications where protection from moisture is required and aluminum
shielding is desired. SEALPIC-FSF may be used aerially, but must be
attached to a support strand.
applications where protection from moisture is required and aluminum
shielding is desired. SEALPIC-FSF may be used aerially, but must be
attached to a support strand.
Applications
• Low risk direct burial
• Underground conduit
• Lashed aerial
• Underground conduit
• Lashed aerial
Features
Benefits
• Twisted into pairs with varying
lay lengths
• Minimizes crosstalk
• Core wrap
• Provides thermal protection
• Filled core
• Moisture resistant
• Fully flooded shield interfaces
• Inhibits corrosion
and water migration
• Black, polyethylene jacket
• Provides a tough, protective
covering designed to withstand
exposure to direct sunlight,
atmospheric temperature
changes and stresses expected
in standard installations