Справочник Пользователя для MEAN WELL CEN-75-24

Скачать
Страница из 3
Features :
75W Single Output LED Power Supply
C E N - 7 5
s e r i e s
SPECIFICATION
MODEL
CEN-75-20
CEN-75-24
CEN-75-30
CEN-75-36
CEN-75-54
CEN-75-15
CEN-75-48
CEN-75-42
DC VOLTAGE
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
20V
24V
30V
36V
54V
15V
48V
42V
0 ~ 3.75A
0 ~ 3.15A
0 ~ 2.5A
0 ~ 2.1A
0 ~ 1.4A
0 ~ 5A
0 ~ 1.57A
0 ~ 1.8A
75W
75.6W
75W
75.6W
75.6W
75W
75.36W
75.6W
2Vp-p
2.7Vp-p
3Vp-p
3.6Vp-p
5Vp-p
2.7Vp-p
4.6Vp-p
4Vp-p
±10%
±3.0%
±5.0%
1400ms / 230VAC    2800ms / 115VAC at full load
90 ~ 295VAC          127 ~ 417VDC
47 ~ 63Hz
PF>0.97/115VAC, PF>0.95/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
88%
89%
90%
90%
91%
87%
91%
90%
22.8 ~ 26V
28 ~ 34V
34 ~ 38V
41 ~ 46V
59 ~ 65V
17.5 ~ 21V
54 ~ 60V
47 ~ 52V
1.1A/115VAC          0.55A/230VAC          0.4A/277VAC
<0.75mA / 240VAC
95 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for  72min. each along X, Y, Z axes
522.2K hrs min.      MIL-HDBK-217F (25
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ofambient temperature.
2. Ripple & noise are measured at 20MHz ofbandwidth by using a 12" twisted pair-wire terminated with a 0.1uf& 47ufparallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. lease refer to "DRIVING METHODS OF LED MODULE".
P
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
0.56Kg;24pcs/14.4Kg/1.11CUFT
Protection type : Shut down o/p voltage, re-power on to recover
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
SAFETY STANDARDS
Compliance to EN55015, EN61000-3-2 Class C (
75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level (surge 4KV),  criteria B
15 ~ 20V
18 ~ 24V
22.5 ~ 30V
27 ~ 36V
40.5 ~ 54V
11.25 ~ 15V
36 ~ 48V
31.5 ~ 42V
RATED CURRENT
3.75A
3.15A
2.5A
2.1A
1.4A
5A
1.57A
1.8A
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
49 ~ 58V
13.5 ~ 17V
43 ~ 53V
37 ~ 46V
VOLTAGE ADJ. RANGE
(SVR1)
CURRENT ADJ. RANGE
(SVR2)
2.81 ~ 3.75A
2.36 ~ 3.15A
1.88 ~ 2.5A
1.58 ~ 2.1A
1.05 ~ 1.4A
3.75 ~ 5A
1.18 ~ 1.57A
1.35 ~ 1.8A
Universal AC input / Full range (up to 295VAC)
Protections: Short circuit /
/ Over voltage / Over temperature
Over current
Output voltage and constant current level adjustable
Built-in active PFC function
IP66 design for indoor or outdoor installations
Class 2 power unit
Cooling by free air convection
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
Features :
File Name:CEN-75-SPEC   2013-11-27
185*62.5*40.5mm (L*W*H)
IP66
SELV
..
UL879, UL8750, CSA C22.2 No.207-M89, CSA C22.2 No.250.0-08, TUV EN61347-1, EN61347-2-13, IP66, J61347-1, J61347-2-13 approved
110
F
M
M
EMC IMMUNITY
EMC EMISSION
COLD START 45A(t
=85   s measured at 50% I
) at 230VAC
width
peak
μ
CONSTANT CURRENT REGION
Note.5