Техническая Спецификация для Cisco 1-port Gigabit Ethernet half-height line card, spare ESR-HH-1GE=

Модели
ESR-HH-1GE=
Скачать
Страница из 7
 
 
Data Sheet 
All contents are Copyright © 1992–2007 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. 
Page 3 of 7 
 
802.2 Service Advertising Protocol (SAP)  
 
802.2 Subnetwork Access Protocol (SNAP)  
Software Features  
 
Autonegotiation  
 
64-bit counters  
 
802.1Q virtual LANs (VLANs)  
 
Hot Standby Router Protocol (HSRP)  
 
Table 2 describes the SFP transceiver specifications.  
Table 2. 
Gigabit Ethernet SFP Transceivers 
SFP Transceiver  
Wavelength (nm)  
Fiber Type  
Core Size 
(microns)  
Modal Bandwidth 
(MHz/km)  
Cable Distance  
1000BASE-SX 
SFP-GE-S=  
(previously  
GLC-SX-MM=)  
850  
Multimode fiber 
(MMF)  
62.5 
62.5 
50.0 
50.0  
160 
200 
400 
500  
722 ft (220m) 
902 ft (275m) 
1,640 ft (500m) 
1,804 ft (550m)  
1000BASE-LX/LH 
SFP-GE-L=  
(previously  
GLC-LH-SM=)  
1300  
MMF
1
 
Single-mode fiber 
(SMF)  
62.5 
50.0 
50.0 
8 to 10  
500 
400 
500 
– 
1,804 ft (550m) 
1,804 ft (550m) 
1,804 ft (550m) 
32,808 ft (10 km)  
1000BASE-ZX 
GLC-ZX-SM=  
1550  
Single-mode fiber 
(SMF) 
9, 10  
– 
43.4 to 62 miles 
(70 to 100 km)
2
  
1000BASE-T 
SFP-GE-T= 
– 
– 
– 
– 
328 ft (100m) 
Environmental Conditions  
 
Storage temperature: –38 to 150°F (–40 to 70°C)  
 
Operating temperature, nominal: 41 to 104°F (5 to 4 0°C)  
 
Operating temperature, short term: 23 to 131°F (–5  to 55°C)  
 
Storage relative humidity: 5 to 95% relative humidity (RH)  
 
Operating humidity, nominal: 5 to 85% RH  
 
Operating humidity, short term: 5 to 90% RH  
 
Operating altitude: –60 to 4000m  
Physical Specifications  
 
Height: 7.8 in. (19.8 cm)  
 
Width: 1.3 in. (3.3 cm)  
 
Depth: 11 in. (27.9 cm)  
                                                 
A mode-conditioning patch cord (part number CAB-GELX-625 or equivalent) is required. If you use an 
ordinary patch cord with MMF, 1000BASE-LX SFPs, and a short link distance (tens of meters), this can cause 
transceiver saturation, resulting in an elevated bit error rate (BER). In addition, when you use the long-reach 
SFP with 62.5-micron-diameter MMF, you must install a mode-conditioning patch cord between the SFP and 
the MMF cable on both the transmit and receive ends of the link. The mode-conditioning patch cord is required 
for link distances greater than 984 ft (300m). 
 
1000BASE-ZX SFP can reach up to 100 km by using dispersion-shifted SMF or low attenuation SMF; the 
distance depends on fiber quality, number of splices, and connectors.