Техническая Спецификация для Cisco AIR-CAP702I-S-K9

Скачать
Страница из 7
 
 
© 2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 5 of 7 
Item 
Specification 
Available Transmit 
Power Settings 
2.4 GHz 
20 dBm (100 mW) 
17 dBm (50 mW) 
14 dBm (25 mW) 
11 dBm (12.5 mW) 
8 dBm (6.25 mW) 
5 dBm (3.13 mW) 
5 GHz 
20 dBm (100 mW) 
17 dBm (50 mW) 
14 dBm (25 mW) 
11 dBm (12.5 mW) 
8 dBm (6.25 mW) 
5 dBm (3.13 mW) 
Note: The maximum power setting will vary by channel and according to individual country regulations. Refer to the product documentation for 
specific details. 
Integrated Antenna 
●  2.4 GHz, gain 3.0 dBi, horizontal beamwidth 360° 
●  5 GHz, gain 5.0 dBi, horizontal beamwidth 360° 
Interfaces 
●  10/100/1000BASE-T autosensing (RJ-45) 
●  Management console port (RJ-45) 
●  DC power connector 
Indicator 
●  Status LED indicates boot loader status, association status, operating status, boot loader warnings, boot loader 
errors 
Dimensions 
(W x L x H) 
●  Access point (without mounting bracket): 7 x 7 x 2 inches (177.6 x 177.6 x 50.4 mm) 
Weight 
●  1.06 lb (0.48 kg) 
Environmental 
Cisco Aironet 702i 
●  Nonoperating (storage) temperature: –22 to 158°F (–30 to +70°C) 
●  Nonoperating (storage) Altitude Test: 25°C, 15,000 ft. 
●  Operating temperature: 32 to 104°F (0 to 40°C) 
●  Operating humidity: 10 to 90% percent (noncondensing) 
●  Operating Altitude Test: 40°C, 9843 ft. 
System Memory 
●  128 MB DRAM 
●  128 MB flash 
Input Power 
Requirements 
●  44 to 57 VDC 
●  Power Supply and Power Injector: 100 to 240 VAC; 50 to 60 Hz 
Powering Options 
●  802.3af Ethernet Switch 
●  Cisco Power Injectors (AIR-PWRINJ5=, AIR-PWRINJ4=) 
●  Cisco Local Power Supply (AIR-PWR-B=) 
Power Draw 
●  9.5W (maximum) 
Note: When deployed using PoE, the power drawn from the power sourcing equipment will be higher by some amount 
dependent on the length of the interconnecting cable. This additional power may be as high as 1.3W, bringing the total 
system power draw (access point + cabling) to 10.8W. 
Warranty 
Limited Lifetime Hardware Warranty 
Compliance 
Standards 
●  Safety: 
◦ 
UL 60950-1 
◦ 
CAN/CSA-C22.2 No. 60950-1 
◦ 
UL 2043 
◦ 
IEC 60950-1 
◦ 
EN 60950-1 
●  Radio approvals: 
◦ 
FCC Part 15.247, 15.407 
◦ 
RSS-210 (Canada) 
◦ 
EN 300.328, EN 301.893 (Europe) 
◦ 
ARIB-STD 33 (Japan) 
◦ 
ARIB-STD 66 (Japan) 
◦ 
ARIB-STD T71 (Japan) 
◦ 
AS/NZS 4268.2003 (Australia and New Zealand) 
◦ 
EMI and susceptibility (Class B) 
◦ 
FCC Part 15.107 and 15.109