Direction of Piping 
 
There are 6 directions allowed, namely,  
• 
horizontally perpendicular to the unit 
• 
vertically down from right 
• 
horizontally out from right 
• 
horizontally out to left 
• 
horizontally out to right 
• 
vertically down from left 
 CAUTION  
• 
Don’t form the piping downward at the left of the 
unit. 
Models: Wall type 
Piping direction 
RAK-18PSA 
RAK-25PSA 
RAK-35PSA 
RAK-18PSAN 
RAK-25PSAN 
RAK-35PSAN 
RAK-18PSPA 
RAK-25PSPA 
RAK-35PSPA 
RAK-18QXA 
RAK-25QXA 
RAK-35QXA 
RAK-50QXA 
RAK-18QPA 
RAK-25QPA 
RAK-35QPA 
RAK-50QPA 
RAK-25PXA 
RAK-35PXA 
RAK-50PXA 
RAK-18PPA 
RAK-25PPA 
RAK-35PPA 
RAK-50PPA 
RAK-60PPA 
RAK-70PPA 
RAK-18PEA 
RAK-25PEA 
RAK-35PEA 
RAK-50PEA 
 
10.1.2 
INSTALLATION OF FLOOR TYPE 
INDOOR (RAF-QXA, RAF-PXA)
 
 
Please read the safety precautions carefully before 
operating the unit. The contents of this section are vital to 
ensure safety. Please pay special attention to the following 
signs. 
WARNING  Incorrect methods of installation may 
cause death or serious injury 
CAUTION   Improper installation may result in 
serious consequences. 
 Make sure to connect earth wire 
 This sign indicates prohibition 
Be sure that the unit operates in proper condition after 
installation. Explain to customer the proper way of operating 
the unit as described in the user’s guide. 
 
 WARNING 
• 
Please request your sales agent or qualified 
technician to install your unit. Water leakage, short 
circuit of fire may occur if you do the installation 
work yourself. 
• 
Please observe the instructions stated in the 
installation manual during the process of installation. 
Improper installation may cause water leakage, 
electric shock and fire. 
• 
Make sure that the units are mounted at locations 
which are able to provide full support of the weight of 
the units. If not, the units may collapse and impose 
danger. 
• 
Observe  the rules and regulations of the electrical 
installation and the methods described in the 
installation manual when dealing with the electrical 
work. Use power cables approved by the authorities 
of your country. 
• 
Be sure to use the specified wire for connecting the 
indoor and outdoor units. Please ensure that the 
connections are tight after the conductors of the wire 
are inserted into the terminals. Improper insertion 
and loose contact may cause over-heating and fire. 
• 
Please use the specified piping set for the correct 
refrigerant gas. Otherwise, this may result in broken 
copper pipes or faults 
• 
When installing or removing an air conditioner, don 
not allow air or moisture to remain in the 
refrigeration cycle. Otherwise, pressure in the 
refrigeration cycle may become abnormally high 
may cause a rupture. 
• 
Be sure to ventilate fully in case refrigerant gas 
leaks while at work. If the refrigerant gas comes into 
contact with fire, poisonous gas might be 
discharged. 
• 
After completion of installation work, check to make 
sure that there is no refrigeration gas leakage. If the 
refrigerant gas leaks into the room, coming into 
contact with fire in a fan-driver heater, space heater, 
etc; poisonous gas may be emitted. 
• 
Unauthorized modifications to the air conditioner 
may be dangerous. If a breakdown occurs, please 
contact a qualified air conditioner technical or 
electrician. Improper repairs may result in water 
leakage, electric shock and fire. 
• 
Be sure to connect the earth wire from power 
supply wire to the outdoor unit and between the 
outdoor and indoor unit. Improper grounding may 
cause electric shock. 
 
 
Horizontally 
perpendicular 
to the unit 
Connection