Catalogue 2013
N T
Y
S RT 
from 1100 to 11000 VA 
Single-phase UPS
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170
UPS
EBM
Back up time (minutes)
NRT2-5000K
Standard
NRT2-5000K
1 x NRT-B7000
NRT2-5000K
2 x NRT-B7000
NRT2-7000K
Standard
NRT2-7000K
1 x NRT-B7000
NRT2-7000K
2 x NRT-B7000
NRT2-9000K
Standard
NRT2-9000K 1 x NRT-B11000
NRT2-9000K 2 x NRT-B11000
NRT2-11000K
Standard
NRT2-11000K 1 x NRT-B11000
NRT2-11000K 2 x NRT-B11000
50% of nominal load
75% of nominal load
100% of nominal load
 
 
 
50% of nominal load
75% of nominal load
100% of nominal load
UPS
EBM
Back up time (minutes)
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170
NRT-U1100
Internal
NRT-U1100
1 x NRT-B1100
NRT-U1100
2 x NRT-B1100
NRT-U1700
Internal
NRT-U1700
1 x NRT-B2200
NRT-U1700
2 x NRT-B2200
NRT-U2200
Internal
NRT-U2200
1 x NRT-B2200
NRT-U2200
2 x NRT-B2200
NRT-U3000
Internal
NRT-U3000
1 x NRT-B3000
NRT-U3000
2 x NRT-B3000
 
 
 
UPS + 1 EBM
UPS + 2 EBM
UPS 
(standard)
NET
y
S
115 A - NET
y
S 118 B GB
UPS + 1 EBM
UPS + 2 EBM
UPS 
N TYS RT 1100-3000 VA - Battery extension
N TYS RT 5000-11000 VA - Battery extension
NET
y
S
116 A - NET
y
S 119 B GB
Control panel
1. 
yellow LED lit. Operation in bypass mode
2. 
Green LED lit. Mains healthy
3. 
OFF button
4. 
 Green LED lit. Normal operation (inverter 
in-line)
5. 
 ON / TEST and buzzer override button
6.  
LED bar. Depending on the situation, this 
 indicates either the charge level or the 
capacity of the battery
7.  
Navigator buttons
8.  
Alphanumeric LCD display
9.
 Green LED lit. Status of the load
NET
y
S
 108 
A
4
2
5
6
3
1
NET
y
S
 110 
A
5
7
2
3
4
8
1
Load
Load
Parallel redundant operation  
for business continuity
To achieve the highest level of availability 
and to power critical utilities, NETyS RT UPS 
modules above 3 kVA can be configured for 
1:1 redundancy.
Redundant operation (1+1) means: the 
system incorporates one more UPS module 
than is needed to protect the load ; in the 
event of a breakdown, it guarantees sufficient 
power supply capacity to the load by 
maintaining online protection.
Parallel technology is based on the principle of 
load sharing, whereby both units are always 
kept active.
In a redundant configuration, overall system 
availability is much higher than a conventional 
UPS system using similar technology.
1+1 redundant configuration does not 
require additional circuits and can therefore 
be set up at a later date, simply by using 
two UPS modules and a collector / manual 
bypass module which simplifies cabling and 
maintenance of the UPS installation.
To further streamline the solution, it is also 
possible to select between operation with 
separate battery or shared battery, which is 
extremely useful in the case of applications 
requiring high levels of autonomy.
9
NET
y
S
 117 A GB
5000 VA - 7000 VA - 9000 VA - 11000 VA
1100 VA - 1700 VA - 2200 VA - 3000 VA