Справочник Пользователя для Hitachi RAC-25FXA RAC25FXA

Модели
RAC25FXA
Скачать
Страница из 706
 
13-2
 
 
 
 
 
13.1  GENERAL CHECK 
ATTENTION: 
–  Turn OFF  
–  Check to ensure that the indoor fan and the outdoor fan 
have stopped before electrical wiring work or a 
periodical check is performed. 
–  Protect the wires, drain pipe, electrical parts, etc. from 
rats or other small animals.  If not protected, rats or 
other small animals may gnaw at unprotected parts and 
at the worst, a fire will occur. 
–  Avoid the wires from touching the refrigerant pipes, plate 
edges and electrical parts inside the unit. Otherwise, the 
wires will be damaged and at the worst, a fire will occur. 
 
CAUTION: 
 
Tightly secure the wires with the cord clamp inside the 
indoor unit. 
NOTE: 
 
Fix the rubber bushes with adhesive when conduit tubes 
to the outdoor unit are not used. 
1.  Make sure that the field-selected electrical components 
(main power switches, circuit breakers, wires, conduit 
connectors and wire terminals) have been properly 
selected according to the electrical data given in this 
technical catalog.  Make sure that the components 
comply with National Electrical Code (NEC). 
2.  Check to ensure that the power supply voltage is within 
±10% of the rated voltage. 
3.  Check the capacity of the electrical wires.  If the power 
source capacity is too low, the system cannot be started 
due to the voltage drop. 
4.  Check to ensure that the ground wire is connected. 
5.  Power Source Main Switch 
Install a multi-pole main switch with a space of 3.5mm or 
more between each phase. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
13.2  ELECTRICAL WIRING FOR 
MONOZONE/MULTIZONE UNIT 
13.2.1 PROCEDURES OF WIRING 
Connect the electrical wiring between the Indoor and 
Outdoor unit, as shown below. Never connect the wiring by 
mistake. 
 
In case of wrong connection, the unit does not operate 
properly and it may cause malfunction. 
The connecting cord must be fixed by the banc which is 
located near the terminal board. 
Connection of connecting cords and power cord 
– 
Cut of the connecting cord, the power cord and strip 
the insulation of the wire. 
– 
Connect the connecting cord and power cord to the 
terminal board. 
– 
Fix the connecting cords and power cord with steel 
band certainly. 
WARNING: 
– 
The naked part of the wire core should be10 mm and 
fix tem tightly to the terminal. Then try to pull the 
individual wireto check if the contact is tight. Improper 
insertion may cause the terminal to burn. 
– 
Be sure to use only power cables approved from the 
authorities from your country. For example in 
Germany: Cable type : NYM 3x1.5mm
2
 
In
d
o
o
r u
n
it
 
In
d
o
o
r u
n
it
 #
1
 
In
d
o
o
r u
n
it
 #
2
 
In
d
o
o
r u
n
it
 #
3
 
S
c
re
w
 f
o
r g
ro
u
n
d
ear
th
 sc
rew
 
S
c
re
w
 f
o
r g
ro
u
n
d
ear
th
 sc
rew
 
S
cr
ew
 f
o
g
ro
u
n
d
, e
a
rt
h
 
 
C
o
n
n
e
c
ti
n
g
 
c
o
rd
 φ
1.
6 o
φ2.
0
 
G
re
n
n
 a
n
d
 
Y
e
llow
 
G
re
n
n
 a
n
d
 
Y
e
llow
 
G
re
n
n
 a
n
d
 
Y
e
llow
 
C
o
n
n
e
c
ti
n
g
 c
o
rd
 
φ1.
6 o
φ2.
0
 
S
c
re
w
 f
o
r g
ro
u
n
d
ear
th
 sc
rew
 
S
c
re
w
 f
o
r g
ro
u
n
d
ear
th
 sc
rew
 
S
c
re
w
 f
o
r g
ro
u
n
d
ear
th
 sc
rew
 
O
u
td
o
o
r u
n
it
 
P
o
w
er
 co
rd
 
S
cr
ew
 f
o
g
ro
u
n
d
ear
th
 
scr
ew
 
G
re
n
n
 a
n
d
 
Y
e
llow