Setting the 
High-Pass Filter 
Setting the PAD
Storage
The High-Pass Filter setting can be used to reduce 
the microphone’s sensitivity to low frequency sounds, 
and is useful when you wish to avoid additional noise 
and vibration from outside traffi c, air conditioning and 
machinery, foot tapping etc.
The middle selector switch on the front of the NT2-A can 
be used to set the High-Pass Filter to 0Hz/Flat (center 
position), 40Hz (lower position) or 80Hz (upper position).
The PAD setting can be used to attenuate the output 
level of the microphone so that it does not exceed the 
maximum input level of your recording device. This is 
useful when recording high SPL sources such as guitar 
amplifi ers or percussion.
The bottom selector switch on the front of the NT2-A can 
be used to set the PAD at 0 (center position), -5dB (lower 
position) or -10dB (upper position).
•  
After use the NT2-A should be removed from its 
mount, wiped with a dry, soft cloth and placed in the 
provided microphone sleeve/dust cover.
•  Be sure to place the moisture-absorbent crystals 
(supplied) at the head of the microphone, so as to 
absorb any moisture present.
•  Eventually this pack of crystals will need to be dried. 
This is indicated by the crystals turning pink in colour.
They can easily be re-used by placing them in an oven 
at 100 - 150 degrees celsius for approximately ten 
minutes. The crystals will operate effectively again 
once they have turned blue.