218
P
RODUCT
 M
ANUAL
 
1016988
A
PPENDIX
 B—I
NTERFACE
 S
PECIFICATION
This section provides requirements and specifications for the SCSI interface, 
including information about the following:

SCSI cable and terminator requirements

SCSI communications

Elements and element addresses
SCSI C
ABLE
 R
EQUIREMENTS
SCSI cables and terminators are included with the library. The wide LVD SCSI 
cable conforms to SCSI-3 specifications. Check the tape drive documentation 
for information about SCSI cable requirements. 
If you want to use your own SCSI cable(s), follow these guidelines:
Use high-density, wide (68-pin) Ultra 160 SCSI cables that conform to SCSI-3 
specifications. To comply with the regulations and standards listed in 
, all SCSI cables used with the library must be properly shielded.  
SCSI T
ERMINATOR
 
REQUIREMENTS
One wide Ultra 3 Active SCSI terminator is provided with the library. If you 
want to use your own terminator, use a high-quality Ultra 3-rated Active SCSI 
terminator. An appropriate terminator is stamped with Ultra 3 or LVD 160 and 
“Active Negation.” 
SCSI C
OMMUNICATIONS
This section provides information about how the library communicates on the 
SCSI bus via the tape drives. As described in this section, a SCSI application 
program communicates with the library through the tape drive(s) via ADI to 
perform the following actions:

Move cartridges between the storage locations and a tape drive

Update and access information stored in the cartridge inventory

Set various operating parameters

Inquire about the status of a specific operation
Caution
Although the tape drive’s wide LVD SCSI interface is compatible with single-ended 
SCSI, Tandberg Data Corporation does not support the use of the tape drives in this 
library on a single-ended bus or on a bus with single-ended devices attached.
All wide SCSI configurations (single-ended, LVD, and HVD) use the same 68-pin 
connector. Attaching the tape drive’s directly to an HVD SCSI bus may cause the 
SCSI bus to hang.
! ! ! ! 
Important
Both LTO-2 and LTO-3 SCSI tape drives require an Ultra 3 or 
LVD 160 terminator to function properly on the SCSI bus. An 
inadequate terminator will result in various SCSI bus issues, 