Справочник Пользователя для Tandberg Data StorageLoader 2U LTO, 1 x 10 LTO-3 052102
![Tandberg Data](https://files.manualsbrain.com/attachments/8271ccef07132c54cceec2de3427e457a84320f2/common/fit/150/50/52df1ed557284065f85b3b090a0c51410202fdbcde102326caf75bb8c845/brand_logo.jpeg)
Модели
052102
224
P
RODUCT
M
ANUAL
1016988
A
PPENDIX
B—I
NTERFACE
S
PECIFICATION
F
IBRE
C
HANNEL
I
NTERFACE
S
PECIFICATIONS
(FC T
APE
D
RIVE
)
Fibre Channel cables are not included with the library. The number of optical
fiber cables required for attaching the library to a Fibre Channel network
depends on how many tape drives are installed.
Each of the tape drive optical fiber ports contains a transmitter and receiver
optical subassembly. The transmitter subassembly contains an internal
semiconductor laser diode that operates at a wavelength of 850 nm
(nanometers).
Use either 50-micron or 62.5-micron multi-mode optical fiber cables with dual
single-channel (LC) connectors.
50-micron multi-mode optical fiber cables must comply with the
400-M5-SN-I classification as specified in the Fibre Channel standard
(FC-PI-2).
62.5-micron multi-mode optical fiber cables must meet the 400-M6-SN-I
classification.
Table B-4 Multi-mode optical cable characteristics
Cable type
Transmitter
Data Rate
(MB/sec.)
Maximum
Distance
50-micron multi-mode
fiber
a
a
Complies with the 400-M5-SN-I classification
850 nm shortwave laser
400
.5 m – 150 m
62.5-micron multi-mode
fiber
b
b
Complies with the 400-M6-SN-I classification
850 nm shortwave laser
400
.5 m – 70 m