Техническая Спецификация для Conrad Energy Rechargeable AAA Battery x1 pc(s) NiMH 1.2V 250901

Модели
250901
Скачать
Страница из 5
Battery Spec.---PH-AAA900mAh  
                                                                     Page  3  of   5
6.Potential
Discharge time of the charged battery specified in
item(1) is measured at 180mA up to an cut-off
voltage of 1.0V .
≥240 minutes
7.Internal
Resistance
The battery is measured at 1000Hz with charge state.
≤30mΩ
8.Over-charge
Charge is conducted continuously for 48 hours at
90mA after the capacity test specified in item(4).
No deformation and
leakage
9.Over-discharge
Discharge is conducted with a 1Ω/cell load for 24
hours.
No  external
deformation
10.Self-discharge
The charged battery specified in item(1) is stored for
28 days at 20 , and the discharge time is measured at
180mA.
≥180 minutes
11.Storage
The capacity test conducted as specified in item(3)
after the battery discharged with 180mA and stored
for 18 months under standard condition.
≥300 minutes
12.Humidity
The charged battery is stored for 10 days at 33±3
and 80±5% of relative humidity.
No electrolyte
leakage
13.Safety Valve
   Operation
Forced discharge is conducted for 30 minutes at a
constant current of 900mA after predischarge at a
constant current of 1800mA up to 0V.
Not explode or
disrupt. 
*
14.External
  Short-circuit
The charged battery specified in item(1) is short-
circuited for 1 hour.
Not explode. 
*
15.Drop Test
The battery is subjected to a drop, which has a height
of 45cm(17.7 inches) to an oak board of 10mm or
more thick in a voluntary axis respectively 3 times.
Mechanically and
electrically normal
Note: 
*
 Electrolyte leakage and deformation of battery are acceptable.
4. Configuration, Dimensions and Markings
   Please refer to the attached drawings.