Data Sheet
Page 2 of 6
4. Performance Testing
4.1. Test conditions
4.1.1 The battery to be tested is the product within one month after being received by customer.
4.1.2 Ambient conditions:
Temperature +20 °C ±5 °C
Humidity 65% ±20%
4.2 Testing Tools
4.2.1 Voltage meter:
0.5 level or higher as required in IEC51/IEC485. Internal impedance exceeds 10 k
Ω/V.
4.2.2 Current meter:
0.5 level or higher as required in IEC51/IEC485. Internal impedance should be less than 0.01 
Ω/V(including wires).
4.2.3. Micrometer caliper: With precision of 0.02 mm.
4.2.4. Internal impedance meter: Alternating current of 1000 Hz, connector measuring equipment with sin wave of 4.
4.2.5: Impedance loaded meter:
Value of impedance is with +5% error allowed (including external wires).
4.2.6 Incubators
Accuracy ±2 °C
4.3 Test methods and benchmarks
Item
Test Method
Benchmark
1. Appearance
Eyeballing
Batteries shall be free from any stains;
scratches or deformations, which may
reduce the commercial value when
visually inspected
2. Size
Caliper measurement
The size shall comply with the specified
size as the attached drawing
3. Insulate impedance
measured with a Megger overpack and battery
electrode between the degree of insulation
Outer sleeve shall exceed 10 M
Ω .
4. Weight
Using disk-scale measurement
Approximate 13.0 g.
5. Charge Voltage
Following a period of discharge at 0.2CmA
down to a terminal voltage of 1.0 V, standard
charge, the cell or battery shall be checked at 5
minutes before finish charging
The voltage shall be less than 1.6 V.
6. Open circuit voltage: (O.C.V.)
Following a standard charge period, the open
circuit voltage of the cell or battery shall be
checked within 1 hour
The O.C.V. shall exceed 1.25 V
7. Closed circuit voltage: (C.C.V.) Following a standard charge period, the closed
circuit voltage of the cell or battery shall be
checked with a 0.86 
Ω per cell load within 1
hour
The C.C.V. shall exceed 1.2 V
8. Internal impedance
Following a standard charge period, the
internal impedance of the cell or battery shall
be checked at 1000 Hz within 1 hour
The internal impedance shall not be
more than 35 m
Ω