Техническая Спецификация для Conrad Energy Rechargeable AA Battery x4 pc(s) NiZn 1.6V 252000

Модели
252000
Скачать
Страница из 7
 
Conrad Electronic SE  · Klaus-Conrad-Str.1 · 92240 Hirschau 
14
.Cycle Life 
             
①Discharge to 1.3V at 300mA;  
②Charge 120 minutes at 750mA constant 
current with a voltage holding at 1.9V;      
③Constant voltage holding at 1.9V to 
charge 90 minutes until current drops to 
50mA;  
④Rest for 15 minutes;  
⑤Discharge to 1.2V at a constant current 
at 1500mA;  
⑥Repeat steps from ② to ⑤ until the 
capacity drops to 60%. 
—  The cycles life shall exceed 
200 times
。 
15
.Leak-proof 
test 
—  Standard charge and store for 14 days 
under the following storage 
conditions
:  33 ±3 , Relative 
humidity: 80%±5%.  
—  No leakage of electrolyte in 
liquid form shall be 
observed
。 
16
.Vibration 
test 
—  Store the cell more than 24 hours 
after standard charge, following 
vibration tests over an amplitude of 4 
mm (0.1575 inches) at a frequency of 
16.7 Hz(1000 cycles per minute) and 
repeated through any axes during 
60mins
。 
— 
The subsequent fluctuation of 
open circuit voltage and 
internal impedance shall be 
less than 0.02  V and   5  mΩ 
respectively, and the surface 
of cell has no obvious change.
 
17
.Free falling: 
(Drop) 
—  Store the cell more than 24 hours 
after standard charge, following a 
drop test from 450mm (17.717 
inches ) on to a hard-wood board in a 
vertical axis 3 times . 
—  The subsequent fluctuation of 
open circuit voltage and 
internal impedance shall be 
less than   0.02  V and   5   mΩ 
respectively, and the surface 
of cell has no obvious change. 
18
.Safety 
testing 
—  to store it for 1 hour after standard 
charged, and to make positive and 
negative electrode short-circuit with a 
wire with the section 0.75mm
min 
and shortest length, the short-circuit 
time is 1 hour 
—  It shall not explode . However, 
leakage of electrolyte, external 
deformation or outer sleeve 
cracking is permitted.
。 
19. Safety Valve 
Start 
Performance 
(Over dis-
charging) 
—  to be charged with  1500  mA for 5 
hours 
—  safety valve can work 
normally, no breakage, 
leakage, distortion and out 
package breakage are allowed 
20.  Safty Valve 
Start 
Performance 
—  to be charged with  1500  mA for 5 
hours 
 
—  No explosion, but leakage, 
distortion and out package