Техническая Спецификация для Conrad Energy 9 V / PP3 battery (rechargeable) NiMH 250 mAh 9 V 1 pc(s) 250024

Модели
250024
Скачать
Страница из 4
5. Internal resistance
After charge at 0.2C
5
 to for 2.5
hours, rest 5 hours, measured at
1000Hz
≤1500mΩ
6. Cycle life
By IEC standard:
Charge (0.25C
5
) for 3h 15min,
discharge (0.25C
5
) for 2h 30 min
Capacity
Retention≥65%
After 500 cycles
7. Self-Discharge
The charged battery is stored for 28
days at 20 ±5 . And the discharge
time is measured at Nominal
discharge
≥180minutes
8. High Temperature Test
Store at 40
50
60  for 2 hours
then Charge/Discharge
No leakage
9. Low Temperature Test
Store at 0  for 2 hours then
charge/discharge
No leakage
10. Short Circuit Test
Short circuit after fully charge
No explode
11. Drop Test
Free fall on the concrete from 1
meter using to 3 axis after fully
charged
No Break
No short-circuit
6 mechanics
48.5m
ax
17.5m
ax
26.5max
12.7
-
+
   with sleeve
7 charge/discharge curve (Charge at 0.1C, discharge at 0.2C)