Техническая Спецификация для Renata 3.7 V 165 mAh (L x W x H) 21.5 x 16 x 6.9 mm 100695

Модели
100695
Скачать
Страница из 13
 
 
 
 
 
 
 
Renata SA 
Tel.  +41 (0)61 975 75 75 
sales@renata.com 
CH-4452 Itingen/Switzerland 
Fax.  +41 (0)61 975 75 95 
www.renata.com 
The information and recommendations set forth are made in good faith and believed to be accurate as of the date of preparation. RENATA S.A. makes no warranty, expressed or implied, with 
respect to this information and disclaims all liabilities from reliance on it.
 
 
 
Article Safety Data Sheet - Lithium Batteries Version: 2011-12-09
 
Page 3 of 13 
 
 
 
 
P102 Keep out of reach of children 
P223 Keep away from any possible contact with water, because of violent reaction and 
possible flash fire 
P232 Protect from moisture 
P260 Do not breathe dust/fume/gas/mist/vapors/spray 
P262 Do not get in eyes, on skin, or on clothing 
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact 
lenses, if present and easy to do. Continue rinsing 
P280 Wear protective gloves / protective clothing / eye protection / face protection 
 
 
 
Section IV - First Aid Procedures 
 
None unless internal material exposure. 
Explanation Carcinogenicity: NOT RELEVANT 
Skin contact with contents of an opened battery can cause irritation, wash immediately with soap and water. Remove 
contaminated clothing. If irritation persists, get medical help 
Eye contact: 
Contents of an opened battery can cause severe irritation, IMMEDIATELY FLUSH THOROUGHLY WITH COPIOUS 
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SEEK MEDICAL ATTENTION. 
Ingestion: 
CALL MEDICAL PRACTIONER IMMEDIAIELY 
Inhalation: 
Do not inhale leaked material. PROVIDE IMMEDIATELY FRESH AIR, IF IRRITATION PERSISTS, GET MEDICAL 
HELP. 
 
Section V - Fire Fighting Instructions 
 
5.1 Fire and explosion hazard: 
The battery can leak and/or spout vaporized or decomposed and combustible 
electrolyte fumes in case of exposure above 70℃ resulting from inappropriate use or 
the environment. 
Cells or batteries may flame or leak potentially hazardous organic vapors if exposed 
to excessive heat or fire. Fire, excessive heat, or over voltage conditions may 
produce hazardous decomposition products. 
Damaged or opened cells or batteries can result in rapid heating and the release of 
flammable vapors. 
Vapors may be heavier than air and may travel along the ground or be moved by 
ventilation to an ignition source and flash back fire, excessive heat, or over voltage 
conditions may produce hazardous decomposition products. 
During water application, caution is advised as burning pieces of flammable particles may be ejected from 
the fire. 
 
5.2 Extinguishing Media: 
Suitable CO
Dry chemical or Foam extinguishers. 
Not to be used : Type D extinguishers. 
Special Fire Fighting Procedure: WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE EQUIPMENT. 
Unusual Fire and Explosion Hazards: NONE SPECIFIED BY MANUFACTURER. 
 
As with any fire, wear self-contained breathing apparatus to avoid inhalation of hazardous decomposition products.