Справочник Пользователя для IBM UPS1500THV TOPSELLER OPTION 74P4932

Модели
74P4932
Скачать
Страница из 4
8 IEC 309-C13
8 IEC 309-C13 
6 IEC 309-C13 
8 NEMA 5-15R
8 NEMA 5-15R
6 NEMA 5-15R
Outlets
IEC 309-C14
IEC 309-C14
IEC 309-C14
• Fixed 2m (6ft)
line cord
•  NEMA 5-15P
• Fixed 2m (6ft)
line cord 
• NEMA 5-15P
• Fixed 2m (6ft)
line cord 
• Nema 5-15P
Input
Information
• 220-240V; nominal
230V
• 1500VA, 1050W
• 220-240V; nominal
230V
• 1000VA, 700W
• 220-240V; nominal
230V
• 750VA, 500W
• 110-127V;
nominal 120V
• 1320VA @ 110V;
1050W
• 1440VA @120V;
1050W
• 1500VA @127V;
1050W
• 110-127V;
nominal 120V
• 1000VA, 700W
• 110-127V;
nominal 120V
• 750VA, 500W
Rated output
21306TX
21304TX
21302TX
21305TX
21303TX
21301TX
Part number
IBM UPS1500THV
IBM UPS1000THV
IBM UPS750THV
IBM UPS1500TLV
IBM UPS1000TLV
IBM UPS750TLV
Model
IBM Tower UPS low- and high-voltage models 
2m UPS serial cable, 2m USB cable, documentation and software CDs. UPS1000T and UPS1500T include
2m CAT5 LAN cable and 2m telephone cable.
Ship group components
FCC, UL 1778, CSA C22.2 Number 950, NOM, CE-Mark (EN55022 Class A), C-Tick Mark (AS/NZS 3548
Class A), VDE EN50091-1-1 and 60950, GOST
Approvals
IBM ^ xSeries Rack Configurator at ibm.com/pc/us/eserver/xseries/library/configtools.html
Configuration aid
Temp: 0-40C (32-104F): relative humidity: 0-95%; altitude (max): 3000m (10,000ft)
Environmental
Serial or USB connections for management; open Smart Slot; hot-swap batteries; Cell Guard intelligent
battery management; overload indicator; replace-battery indicator; site wiring fault indicator (LV only);
automatic voltage regulation (AVR); status indicator LEDs
General features
3-year limited onsite warranty provided worldwide by IBM
Warranty
1
Black
Black
Black
Color
21.6x17.0x43.4cm 
18.5x6.7x17.3in
21.6x17.0x43.4cm 
18.5x6.7x17.3in
21.6x17.0x43.4cm
18.5x6.7x17.3in
Dimensions (HxWxD)
24.1kg (53lbs)
19.1kg ( 42 lbs)
19.1kg (42 lbs)
Weight
• Full load:  7 minutes
• Half load:  16 minutes
• Full load:  9 minutes
• Half load:  18 minutes
• Full load:   6 minutes
• Half load:  12 minutes
Battery backup times
Microsoft® Windows NT® 4.0, Windows® 2000, Windows XP, Novell NetWare 6.0, Red Hat Linux 7.3
Software support
PowerChute Business Edition for IBM, PowerChute Network Shutdown for IBM
Software included
USB, serial
USB, serial
USB, serial
Connections for
management
Online: 95%; on battery: 98%
Online: 95%; on battery: 98%
Online: 95%; on battery: 98%
Efficiency
47/63Hz (auto adjusting)
47/63Hz (auto adjusting)
47/63Hz (auto adjusting)
Input frequency
Tower
Tower
Tower
Form Factor
IBM UPS1500T
IBM UPS1000T
IBM UPS750T
Model
IBM Tower UPS family at a glance
3