Справочник Пользователя для Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S
Модели
MSO1074Z-S
RIGOL
2-60
DS1000Z Programming Guide
:MEASure:STATistic:RESet
Syntax
:MEASure:STATistic:RESet
Description
Clear the history data and make statistic again.
Related
Command
:MEASure:STATistic:ITEM
Syntax
:MEASure:STATistic:ITEM <item>[,<src>[,<src>]]
:MEASure:STATistic:ITEM? <type>,<item>[,<src>[,<src>]]
:MEASure:STATistic:ITEM? <type>,<item>[,<src>[,<src>]]
Description
Enable the statistic function of any waveform parameter of the specified source, or query
the statistic result of any waveform parameter of the specified source.
Parameter
Name
Type
Range
Default
<item> Discrete
{VMAX|VMIN|VPP|VTOP|VBASe|VAMP|VAVG|
VRMS|OVERshoot|PREShoot|MARea|MPARea|
PERiod|FREQuency|RTIMe|FTIMe|PWIDth|
NWIDth|PDUTy|NDUTy|RDELay|FDELay|
RPHase|FPHase}
——
<src>
Discrete
{CHANnel1|CHANnel2|CHANnel3|CHANnel4}
See
Explanation
<type> Discrete
{MAXimum|MINimum|CURRent|AVERages|
DEViation}
——
Explanation
The [,<src>[,<src>]] parameter sets the source of the parameter to be measured.
If the parameter to be measured needs single source (such as VMAX, VMIN, VPP,
VTOP, VBASe, VAMP, VAVG, VRMS, OVERshoot, MARea, MPARea, PREShoot, PERiod,
FREQuency, RTIMe, FTIMe, PWIDth, NWIDth, PDUTy, NDUTy, etc.), one source
requires to be set. If the [,<src>[,<src>]] parameter is omitted, the default source is
selected by the
If the parameter to be measured needs two sources (such as RDELay, FDELay,
RPHase, FPHase, etc.), two sources need to be sent with the command. If else, the
command will be invalide. If the [,<src>[,<src>]] parameter is omitted, the default
and
Return
Format
The query returns the statistic result in scientific notation.
Example
:MEASure:STATistic:ITEM VPP,CHANnel2 /*Enable the Vpp statistic function of CH2*/
:MEASure:STATistic:ITEM? MAXimum,VPP /*The query returns 9.120000e-01*/
Related
Command