Справочник Пользователя для Lecroy WSXS-SPIBUS TD WSXS-SPIBUS TD trigger and decoder extension Compatible with LeCroy WaveSurfer® oscilloscopes. WSXS-SPIBUS TD

Модели
WSXS-SPIBUS TD
Скачать
Страница из 204
Operator's Manual 
919586 RevA 
83 
Include or exclude Channel Idle Delimiter (CID)CAS/MTS, or Wakeup Pattern from your trigger by 
checking our un-checking as desired. Multiple values may be selected and included in your Symbol 
trigger. 
E
RRORS 
T
RIGGER 
S
ETUP 
D
ETAIL
 
4c. Protocol and CRC Errors - Error Trigger Only 
When Errors is selected as the FlexRaybus trigger, use the Protocol and CRC Errors fields in the following 
manner: 
 
 
Protocol Errors - Include or exclude FSSBSS, or FES errors from your trigger by checking our un-checking 
as desired. 
 
CRC Errors - Include or exclude Header CRC or Payload CRC errors from your trigger by checking our un-
checking as desired. 
 
Payload Channel - If you include Payload CRC errors in your Error trigger, use this field to select the 
correct channel.  
 
Select all Errors and Deselect all Errors - Use these buttons to conveniently select or deselect all Protocol 
and CRC Errors with a single click. 
FlexRaybus Physical Layer and Eye Diagram Analysis 
LeCroy's FlexRaybus option contains a software algorithm which creates eye diagrams, performs mask testing 
and measures timing parameters as defined in the FlexRay specification. The algorithm creates eye diagrams by 
slicing up all the bits transmitted in the FlexRay signal and superimposing each bit on to an eye diagram. The 
signal is sliced based on measurements taken at the falling edge of the first Bytes Start Sequence (BSS) and the 
time between consecutive BSS symbols. These measurements allow the algorithm to compute the rate of the 
embedded clock and slice the FlexRay waveform in to sub-waveforms one bit in length. The clock uses a 
constant bitrate specified by the user and is resynchronized on every BSS. These sub-waveforms are then scaled 
to fill 8 horizontal divisions on the oscilloscope and represent 1 Unit Interval (UI) in the eye diagram and 
superimposed on top of each other. 
Mask testing can be performed on the eye diagram with masks defined at TP1 and TP4. The mask is aligned 
horizontally by computing the time for a single UI and centering it on the display. The mask is centered vertically 
around 0V. 
Along with eye diagrams and mask testing the TDP option adds 4 FlexRay specific measurements to the 
oscilloscope. These measurements are Propagation DelayAsymmetric DelayTruncation, and Jitter. They are 
measured as defined in the FlexRay specification. These measurements characterize timing properties of the 
propagation of signals along the communication channel.