Conducting tests with the TG uni 1 appliance tester:
in accordance with DIN VDE 0701 and DIN VDE 0702, PC II
Connecting the test object
– Connect one end of the test line to the probe socket of the tester.
– Use the crocodile clip to connect the other end of the test line with a
– Connect one end of the test line to the probe socket of the tester.
– Use the crocodile clip to connect the other end of the test line with a
touchable metal part of the housing of the test object.
Ensure that the crocodile clip makes a good contact with the metal part of
the test object.
Ensure that the crocodile clip makes a good contact with the metal part of
the test object.
– Connect the mains plug of the test object with the test socket of the tester.
– Switch on the test object with the mains switch.
– Switch on the test object with the mains switch.
Switching on the appliance tester
Connect the mains plug of the tester to a properly connected and functional
earthed mains socket. Switch on the tester with the mains switch.
Press the large button in the Switch-on display (Fig. 33).
Connect the mains plug of the tester to a properly connected and functional
earthed mains socket. Switch on the tester with the mains switch.
Press the large button in the Switch-on display (Fig. 33).
Entering the test date
The test date is entered or confirmed in the following display (Fig. 33a).
The test date is entered or confirmed in the following display (Fig. 33a).
The tester is not equipped with a real-time clock!
Settings for measuring
Press the function button [Test procedure according to standard] in the Main
menu (Fig. 34).
A display with the ‘Settings for measuring’ appears (Fig. 35).
The standard VDE 0701 is preset – change with the [Standard] button. The
protection class is set with the [PC] button (Presetting: PC I). Press the
[PC] button to change the setting to protection class II. Selection of the test
procedure – with or without insulation resistance – is specified with the [Ins
y/n] button.
The headline shows the set measuring method for touch current [DIR.] or
[DIF.] (see ‘Configuration menu’ Point 6.3) and the setting for the manual [H]
or automatic [A] test procedure.
The status line provides information about the current settings throughout the
test procedure.
Press the function button [Test procedure according to standard] in the Main
menu (Fig. 34).
A display with the ‘Settings for measuring’ appears (Fig. 35).
The standard VDE 0701 is preset – change with the [Standard] button. The
protection class is set with the [PC] button (Presetting: PC I). Press the
[PC] button to change the setting to protection class II. Selection of the test
procedure – with or without insulation resistance – is specified with the [Ins
y/n] button.
The headline shows the set measuring method for touch current [DIR.] or
[DIF.] (see ‘Configuration menu’ Point 6.3) and the setting for the manual [H]
or automatic [A] test procedure.
The status line provides information about the current settings throughout the
test procedure.
Fig. 35
Fig. 33
Fig. 34
29
Operating manual for the TG uni 1 appliance tester
Conducting tests in accordance with VDE 0701 and 0702 - PC II
f
f
f
Headline
Status line
Limit values line
f
Fig. 33a
Test procedure:
- manual [H]
- automatic [A]
&
&
&
&
&