Introduction
Congratulations on your purchase of the Extech MO280 Moisture Meter. This
device non-invasively measures and displays moisture content (%) in wood,
building products, and other materials. The MO280 can also detect moisture
behind ceramic tiles or behind and under various floor or wall coverings, on
fabric/cloth and on paper products. This professional meter, with proper care, will
provide years of safe reliable service.
device non-invasively measures and displays moisture content (%) in wood,
building products, and other materials. The MO280 can also detect moisture
behind ceramic tiles or behind and under various floor or wall coverings, on
fabric/cloth and on paper products. This professional meter, with proper care, will
provide years of safe reliable service.
Theory of Operation
The square sensor on the rear of the instrument sends and receives a low power
electromagnetic signal through the material under test. The LCD shows the
average moisture content (in %) of the material under test to a max. depth of
20mm. Moisture that is closer to the surface of the material under test has a
greater effect on the average than moisture deeper in the material. The MO280
is an auto-calibration device; no user calibration is needed.
electromagnetic signal through the material under test. The LCD shows the
average moisture content (in %) of the material under test to a max. depth of
20mm. Moisture that is closer to the surface of the material under test has a
greater effect on the average than moisture deeper in the material. The MO280
is an auto-calibration device; no user calibration is needed.
Description
1. Moisture reading
2. Low battery icon
3. Material group number 0-9
4. Data Hold icon
5. Keypad
Note: Sensor, battery compartment, and ON/OFF
switch on reverse side of meter
switch on reverse side of meter
Operation
1.
Slide the rear power switch to the ON position
2.
IMPORTANT: Hold the meter up so that the rear sensor is not covered by
your hand or any surface or object. If the meter emits chirping tones, the
sensor is entirely or partially covered
your hand or any surface or object. If the meter emits chirping tones, the
sensor is entirely or partially covered
3.
Momentarily press the MEASURE button to activate the sensor (the LCD
display will switch on)
display will switch on)
4.
Press and hold the UP or DOWN button to select a material group 0 to 9 (see
table below). When the desired group is displayed, release the button. The
meter will briefly chirp
table below). When the desired group is displayed, release the button. The
meter will briefly chirp
5.
Firmly press the meter to a smooth flat surface with the sensor side of the
meter (back) touching the material under test and wait for the display to
stabilize; Note the value on the LCD.
meter (back) touching the material under test and wait for the display to
stabilize; Note the value on the LCD.
6.
The meter’s audible tones will sound as the reading changes. A blinking
reading with an urgent chirping sound indicates that the measurement is out
of the range of the instrument’s capability. Try another range by selecting
another material group (see material group & range tables below)
reading with an urgent chirping sound indicates that the measurement is out
of the range of the instrument’s capability. Try another range by selecting
another material group (see material group & range tables below)
7.
Press the HOLD button to freeze a displayed reading. To unfreeze, press the
HOLD button again.
HOLD button again.
8.
If the meter goes into sleep mode, press the MEASURE button to wake it up.
If the meter does not wake or if the low battery icon appears on the LCD,
replace the 9V battery located in the rear battery compartment
If the meter does not wake or if the low battery icon appears on the LCD,
replace the 9V battery located in the rear battery compartment
9.
Turn the rear power switch to OFF when meter is not in use. This will optimize
the battery life
the battery life
Measurement Considerations
The thickness of the sample under test must be at least 3/4” (20mm). If the
sample is thinner, use a stack of samples to measure. Also, the measurement
area of the sample should be larger than the MO280 sensor area which is 1.6 x
1.6” (40 x 40mm).
sample is thinner, use a stack of samples to measure. Also, the measurement
area of the sample should be larger than the MO280 sensor area which is 1.6 x
1.6” (40 x 40mm).
General Specifications
Max. Measurement depth: 20mm (0.75”)
Sensor area
Sensor area
40 x 40mm (1.6” x 1.6”)
Battery type:
9V (rear compartment)
Display:
LCD with sleep mode
Operating conditions:
0
º
C to 50
º
C (32
º
F to 122
º
F)
0 to 60%RH (non-condensing)
Meter Dimensions:
70 x 133 x 25.4mm (2.75x 5.25x 1.0”)
Weight:
160g (5.6 oz) with battery
Battery Replacement
You, as the end user, are legally bound (Battery ordinance) to return all
used batteries and accumulators; disposal in the household garbage
is prohibited!
used batteries and accumulators; disposal in the household garbage
is prohibited!
You can hand over your used batteries / accumulators, gratuitously, at
the collection points for our branches in your community or wherever
batteries / accumulators are sold!
batteries / accumulators are sold!
Disposal: Follow the valid legal stipulations in respect of the disposal of
the device at the end of its lifecycle
the device at the end of its lifecycle
Cautions
• This device is not a toy and must not reach children’s hands. It contains
hazardous objects as well as small parts that the children could swallow. In
case a child swallows any of them, please contact a physician immediately
case a child swallows any of them, please contact a physician immediately
• Do not leave the battery and packing material lying around unattended; they
can be dangerous for children if they use them as toys
• In case the device is going to be unused for an extended period of time,
remove the battery to prevent them from draining
• Expired or damaged batteries can cause cauterization on contact with the skin.
Always, therefore, use suitable hand gloves in such cases
• See that the battery is not short-circuited. Do not throw the battery into a fire.
Wood and Material Group Numbers
Measurement at 73
o
F (23
o
C)
No. Name
No. Name
4 Abachi
4 Mahogany
5 Abura
5 Maple,
Bigleaf
6 Afrormosia
5 Maple,
Red
5 Agba
6 Maple,
Sugar
4 Alder
6 Meranti
5 Ash
6 Oak
Red
4 Aspen
7 Oak,
White
4 Basswood
7 Pecan
6 Beech
4 Pine
Eastern
White
6 Birch
4 Ponderosa
4 Cedar,
Eastern
5 Red
3 Cedar,
Western 4 Southern
Yellow
5 Cherry
4 Poplar
4 Chestnut
5 Ramin
3 Cottonwood
4 Redwood
4 Cypress
8 Rosewood
7 Dogwood
5 Sassafras
5 Douglas
Fir
4 Spruce
5 Elm
5 Sycamore
5 Gum,
Red
5 Teak
4 Hemlock
6 Walnut,
Black
7 Hickory
4 Willow
5 Koa
3 Cloth
5 Lauan,
White
3 Cotton
3 Lauan,
Red
9 Dry
wall
5 Larch
3 Fabric
4 Limba
9 Paper
6 Locust,
Black
5 Plywood
Group No.
Range
0
23.4 to 79.9%
1
33.4 to 89.9%
2
43.4 to 99.9%
3
6.8 to 63.3%
4
6.7 to 63.2%
5
5.4 to 61.9%
6
3.4 to 59.9%
7
1.6 to 58.1%
8
0.4 to 56.9%
9
0.0 to 56.5%
Copyright © 2007 Extech Instruments Corporation