Справочник Пользователя для Greisinger GMH 1150 Digital Thermometer 604208

Модели
604208
Скачать
Страница из 4
H47.0.01.6C-02
page 2 of 2
 Safety Advices
This device has been designed, assembled and tested in accordance with the safety regulations for electronic measurement
devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures and special
safety advices will be adhered to when using the device.
1. Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to any other
climatic conditions than those stated under "Specification".
2. Moving the device from a cold to a warm environment may lead to malfunctions due to condensation. In such a case we
recommend waiting to allow device temperature to adjust to the ambient temperature before re-starting.
3. If device is to be connected to other devices the circuitry has to be designed most carefully. Internal connection in third
party units (e.g. connection GND and earth) may result in not-permissible voltages impairing or destroying the device or
another device connected.
Warning:  If device is operated with a defective mains power supply (short circuit from mains voltage to output voltage)
this may result in hazardous voltages at the device (e.g. sensor socket).
4. If there is any risk whatsoever involved in running it, the device has to be switched off immediately and to be marked
accordingly to avoid re-starting.
Operator safety may be a risk, if :
 - there is visible damage done to the device.
 - the device is not working as specified.
 - the device has been stored under unsuitable conditions for a longer time.
In case of doubt, please return device to manufacturer for repair or maintenance
Temperature
Display
-50
-46
-40
-37
-30
-28
-20
-19
-10
-10
0
0
10
10
20
20
30
29
40
39
50
49
60
59
70
70
80
80
90
90
100
100
110
110
120
120
130
130
140
140
150
150
Temperature
Display
160
160
170
169
180
179
190
189
200
198
210
208
220
218
230
228
240
238
250
248
260
258
270
268
280
278
290
288
300
298
310
308
320
318
330
328
340
339
350
349
360
359
Temperature
Display
370
369
380
379
390
390
400
400
410
410
420
421
430
431
440
441
450
452
460
462
470
472
480
483
490
493
500
504
510
514
520
524
530
535
540
545
550
556
560
566
570
576
Temperature
Display
580
587
590
597
600
607
610
618
620
628
630
639
640
649
650
659
660
670
670
680
680
690
690
700
700
711
710
721
720
731
730
741
740
751
750
762
760
772
770
782
780
792
Temperature
Display
790
802
800
812
810
822
820
832
830
842
840
852
850
862
860
871
870
881
880
891
890
901
900
911
910
920
920
930
930
940
940
949
950
959
960
969
970
978
980
988
990
997
Temperature
Display
1000
1007
1010
1016
1020
1026
1030
1035
1040
1045
1050
1054
1060
1063
1070
1073
1080
1082
1090
1091
1100
1100
1110
1110
1120
1119
1130
1128
1140
1137
1150
1146
1160
1155
1170
1164
1180
1173
Correction table
Recalibration:
The measuring device will be calibrated before leaving our works. A recalibration is, therefore, not necessary. If you want to
calibrate the device for an existing sensor, please proceed as follows: (calibrate 0°C before scale as otherwise correct
adjustment cannot be guaranteed). Normally sensor adjustment by means of 0° C potentiometer is sufficent. We do not
recommend a scale compensation in order to maintain the specified accuracy of the device. If an accurate reference
temperature is available, choose highest temperature possible to calibrate the device.
Calibration point 0°C: Put ice cubes in a glass and pour cold water till ice cubes are
almost covered. Put sensor into glass, wait approx. 15 minutes, then stirr water with
a spoonhandle. Wait for stable value to be displayed, then turn zero point
potentiometer (NP, Potentiometer next to sensor connection) by means of a
screw driver till display shows "000".
Calibration point scale: To set the pitch (Scale) a fixed reference temperature is
required (the higher the better). Subject sensor to this temperature and set respective
display value according to correction table value (e.g. reference temperature 700°C
-> value to be set: 711) by means of pitch potentiometer (outer potentiometer).
Please note that boiling water should not be used as a temperature reference as the boiling temperature is dependent on the
atmospheric pressure.(If using a reference thermometer stating the precise temperature you may, however even use boiling water.)
Please note : During the waiting time the device should have assumed ambient temperature (we recommend a temperature
of 20 to 25°C). Please avoid holding device in your hand as well as subjecting it to an additional heat source (e.g. radiator,
lamp, sun).
Sensor Socket
View of frontplate
Scale
NP