Техническая Спецификация для Conrad Energy Alkaline Size D Battery x1 pc(s) 658013

Модели
658013
Скачать
Страница из 5
 
                                          PRODUCT SPECIFICATION
Product 
Alkaline battery, 1.5 volts 
Page 
3 of 5 
Size 
LR20, Mono, D 
 
 
Conrad Electronic SE, Klaus-Conrad-Straße 1, 92240 Hirschau, Germany 
Tel. 0180/5312111, Fax 0180/5312110, webmaster@conrad.de, www.conrad-energy.de, www.conrad.de 
13. 
Safety test (Test environment: 20
℃±2,60%±15%R.H) 
Test item 
Test method 
Test pcs  Requirements
2.2 ohms (24h/d) 48hours 
9pcs 
No leakage 
2.2 ohms (4min/h, 8h/d) to 0.6V 
9pcs 
No leakage 
2.2 ohms (1h/d) to 0.6V 
9pcs 
No leakage 
10 ohms (4h/d) to 0.6V 
9pcs 
No leakage 
Over-discharge 
leakage test 
3.9 ohms (1h/d) to 0.6V 
9pcs 
No leakage 
High temperature 
test 
60
±2℃,RH:90±5%, after 20 days storage, the cells shall 
be stored in an ambient temperature of 
20
±2℃,RH:60±5%, for 4-24hours. 
40 No 
leakage 
One piece of 
battery Short 
circuit test 
The terminal of an un-discharged battery is connected 
by wire. The circuit is completely for 24hours or until the 
case temperature has return to environment. 
10 
No leakage 
No explosion 
Reversible charge 
4 pieces of battery are in series connected and one of 
them is under incorrect polarity for 24 hours or until the 
case temperature has return to environment.. 
40 No 
explosion 
Over discharge 
One battery discharge 20 ohms to 0.6V, then in series 
connect with 3 pieces of new battery with 20ohm 24h  
36 No 
explosion 
Four pieces of 
battery in series 
Short circuit test 
The terminal of four pieces of battery is connected by 
wire. The circuit is completely for 24hours or until the 
case temperature has return to environment. 
40 No 
explosion 
Free fall test 
The battery free drops from one-meter height for 6 
times, then store for 1h 
10 No 
explosion 
Impact under high 
and low 
temperature 
Un-discharged battery store in test box under 70
±2℃ for 
24h,then change to -20
℃ for 24h, repeat the above 
condition for 10 cycles. 
20 No 
explosion 
Storage after 
partial discharge 
50% discharged battery stored under 45
±5℃ for 30days 
No leakage 
No explosion 
 
14. Expiry 
period: 
7 years 
 
15. 
Expiry period marking: 
Expiry date marked on the bottom plate of finished battery . For example: 2015-08 means the expiry date is 
August 2015.