10. Emergency procedures
Steps to be taken if materials is released to the environment or spilled in the work area:
Notify safety personnel of large spills. Slight caustic zinc chloride and Ammonium chloride may be released from leaking or
ruptured batteries. Avoid eye or skin contact and inhalation of vapors. Increase ventilation. Clean-up personnel should wear
appropriate protective gear.
Fire and explosion hazard:
In case of fire, carbon dioxide, carbon monoxide and other toxic organic substances will be generated. Do not inhale fumes
and smoke.
Extinguishing media:
Carbon dioxide, foam, dry chemical power.
Extinguishing media not to be used:
Never use a direct water jet.
Firefighting Procedures:
Use self-contained breathing apparatus and full protective gear.
11. First aid and medical emergency procedures
Eyes:
Not anticipated. If battery is leaking and material contacts eyes:
First :flush eyes thoroughly with tepid water for 15 minutes.
Second: flush eyes with 3% H3BO3 (Boracic Acid)
Third: Contact physician at once.
Skin:
Not anticipated. If battery is leaking and material contacts eyes, flush with copious amounts of clear, tepid water for 15
minutes. If irritation, injury or pain persists, consult a physician.
Inhalation:
Not anticipated. Rinse the mouth and surrounding area with clear, tepid water for at least 15 minutes. Consult a physician
immediately for treatment and to rule out involvement of the esophagus and other tissues.
12. Toxicological information
The product is multi component mixture for which no toxicological date exists.
13. Ecological information
In general, no ecological data is available for preparations.
Precautions avoid disposing into drainage systems and in the environment.