Справочник Пользователя для Intel SC5400LXI

Скачать
Страница из 104
Intel® Server Chassis SC5400 5U Kit TPS 
Hot Swap Hard Disk Drive Bays 
Revision: 1.0 
 
 
53
6.1.1.1 I
2
C Serial Bus Interface 
The VSC410* controller supports four independent I
2
C interfaces with bus speed of up to 400 
Kbits. The I
2
C bus 0 supports an AT24C64* EEPROM or equivalent I
2
C -based EEPROM used 
as FRU. The I
2
C bus 1 supports a TI TMP75* or equivalent I
2
C -based temperature sensor. This 
enables actual temperature value readings to be returned to the host. The Intelligent Platform 
Management Bus (IPMB) is supported through the I
2
C port 2. The SCSI Enclosure Service 
(SES) interface is supported through the I
2
C port 3. 
The following figure provides a block diagram of I
2
C bus connection implemented on the 4HDD 
and 6HDD passive SAS/SATA HSBP.  
 
Figure 21. 
Passive SAS/SATA HSBP 
I
2
C
 Bus Connection Diagram 
 
6.1.1.2 I
2
C Bus Address and Loading 
Table 40. I
2
C Bus Addressing 
TMP75
*
 I
2
C Address 
AT24C64* I
2
C Address 
VSC410* I
2
C port2 
90h 
A0h 
C0h or C2h