Справочник Пользователя для Intel SC5400LXI
Intel® Server Chassis SC5400 5U Kit TPS
Hot Swap Hard Disk Drive Bays
Revision: 1.0
53
6.1.1.1 I
2
C Serial Bus Interface
The VSC410* controller supports four independent I
2
C interfaces with bus speed of up to 400
Kbits. The I
2
C bus 0 supports an AT24C64* EEPROM or equivalent I
2
C -based EEPROM used
as FRU. The I
2
C bus 1 supports a TI TMP75* or equivalent I
2
C -based temperature sensor. This
enables actual temperature value readings to be returned to the host. The Intelligent Platform
Management Bus (IPMB) is supported through the I
Management Bus (IPMB) is supported through the I
2
C port 2. The SCSI Enclosure Service
(SES) interface is supported through the I
2
C port 3.
The following figure provides a block diagram of I
2
C bus connection implemented on the 4HDD
and 6HDD passive SAS/SATA HSBP.
Figure 21.
Passive SAS/SATA HSBP
I
2
C
Bus Connection Diagram
6.1.1.2 I
2
C Bus Address and Loading
Table 40. I
2
C Bus Addressing
TMP75
*
I
2
C Address
AT24C64* I
2
C Address
VSC410* I
2
C port2
90h
A0h
C0h or C2h