Техническая Спецификация для Conrad Energy 12V Ah lead acid battery, 250915

Модели
250915
Скачать
Страница из 2
 
CP1290
 12V9Ah
 
The  rechargeable  batteries  are  lead-lead  dioxide  systems.  The  dilute  sulfuric  acid  electrolyte  is 
absorbed  by  separators  and  plates  and  thus  immobilized.  Should  the  battery  be  accidentally 
overcharged producing hydrogen  and  oxygen, special one-way valves  allow the gases to  escape thus 
avoiding  excessive  pressure  build-up.  Otherwise,  the  battery  is  completely  sealed  and  is,  therefore, 
maintenance-free, leak proof and usable in any position. 
Construction 
Component 
Positive plate 
Negative plate 
Container 
Cover 
Safety valve 
Terminal 
Separator 
Electrolyte 
Raw material 
Lead dioxide 
Lead 
ABS 
ABS 
Rubber 
Copper 
Fiberglass 
Sulfuric acid 
                                                         
Absorbent Glass Mat (AGM) technology for 
efficient gas recombination of up to 99% and 
freedom from electrolyte maintenance or water 
adding. 
Not restricted for air transport-complies with 
IATA/ICAO Special Provision A67. 
UL-recognized component. 
Can be mounted in any orientation. 
Computer designed lead, calcium tin alloy grid for 
high power density. 
Long service life, float or cyclic applications. 
Maintenance-free operation. 
Low self discharge. 
Case and cover available in both standard and 
flame retardant ABS.
 
Dimensions and Weight 
 
 
 
 
 
 
 
 
 
 
Page  1  of  2                                                   
Battery model 
CP1290
ominal voltage 
12V 
Number of cell 
20hR(0.45A, 
10.5V) 
10hR(0.86A, 
10.5V) 
5hR(1.57A, 
10.5V) 
1hR(6.66A, 
9.60V) 
Capacity   
(25℃) 
9Ah 
8.6Ah 
7.85Ah 
6.66Ah 
Length 
Width 
Height 
Total Height 
Dimensions 
151
±1mm 
65
±1mm 
94
±1mm 
100
±1mm 
Approx. weight 
2.78Kg (6.13 lbs) 
Internal resistance 
Full charged at 25℃: 11mOhms 
Self discharge 
3% of capacity declined per month at 20℃  (average) 
Discharge 
Charge 
Storage 
Operating 
temperature range 
-20~60℃ 
-10~60℃ 
-20~60℃ 
Max. discharge 
current (25℃) 
135A (5s) 
Short circuit 
current 
450A 
Discharge Constant Current (Amperes at 77
o
F25
o
C)
 
End Point 
Volts/Cell 
5min  10min  15min  30min 
1h 
3h 
5h 
10h 
20h 
1.60V 
36.1 
25.2 
19.3 
11.6 
6.66 
2.59 
1.62 
0.88 
0.47 
1.65V 
34.6 
24.3 
18.5 
11.1 
6.42 
2.53 
1.61 
0.87 
0.47 
1.70V 
33.1 
23.3 
17.7 
10.5 
6.18 
2.46 
1.59 
0.87 
0.46 
1.75V 
31.6 
22.2 
16.9 
9.86 
5.94 
2.39 
1.57 
0.86 
0.45 
1.80V 
30 
21.2 
16.1 
9.21 
5.68 
2.32 
1.55 
0.85 
0.44 
Discharge Constant Power (Watts at 77
o
F25
o
C)
 
End Point 
Volts/Cell 
5min  10min  15min  30min  45min 
1h 
2h 
3h 
5h 
1.60V 
74.1 
47.2 
35.1 
21.5 
15.9 
12.4 
6.85 
4.84 
3.27 
1.65V 
70.5 
45.6 
34 
20.8 
15.3 
12 
6.72 
4.79 
3.24 
1.70V 
66.9 
43.9 
32.9 
20.0 
14.7 
11.5 
6.59 
4.74 
3.21 
1.75V 
63.3 
42.2 
31.8 
19.2 
14.1 
11 
6.46 
4.69 
3.18 
1.80V 
59.7 
40.5 
30.7 
18.4 
13.5 
10.5 
6.32 
4.64 
3.15 
 
General Features                             Technology Parameter