Техническая Спецификация для Vision Akkus VISION 6FM200DX, 12V Ah lead acid battery 6FM200DX 6FM200DX

Модели
6FM200DX
Скачать
Страница из 2
 
 
 
6FM200D
   
12V 200Ah(10hr)
 
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid 
electrolyte is absorbed by separators and plates and thus immobilized. Should the 
battery be accidentally overcharged producing hydrogen and oxygen, special one-
way valves allow the gases to escape thus avoiding excessive pressure build-up. 
Otherwise, the battery is completely sealed and is, therefore, maintenance-free, 
leak proof and usable in any position. 
 
Battery Construction
Component
Positive plate
Negative plate
Container
Cover
Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Copper
Fiberglass
Sulfuric acid
General Features 
●     
Absorbent Glass Mat (AGM) technology 
for efficient gas recombination of up to 
99% and freedom from electrolyte 
maintenance or water adding.
●     
Not restricted for air transport-complies 
with IATA/ICAO Special Provision A67.
●     
UL-recognized component.
●     
Can be mounted in any orientation.
●     
Computer designed lead, calcium tin alloy 
grid for high power density.
●     
Long service life, float or cyclic 
applications.
●     
Maintenance-free operation.
●     
Low self discharge.
Dimensions and Weight
  Length(mm / inch)
522 / 20.55
  Width(mm / inch)
238 / 9.37
  Height(mm / inch) 
218 / 8.58
  Total Height(mm / inch) 
240 / 9.45
  Approx. Weight(Kg / lbs) 
65 / 143.3 
 
 
 
 
Performance Characteristics 
Nominal Voltage
12V
Number of cell
6
Design Life 
10 years 
Nominal Capacity 77
o
F(25
o
C)
 
 
  10 hour rate (20.0A, 10.8V)
200Ah
  5 hour rate (34.9A, 10.5V)
174.5Ah
  1 hour rate (130A, 9.6V)
130Ah
Internal Resistance
 
  Fully Charged battery 77
o
F(25
o
C)
3.5mOhms 
Self-Discharge
 
  3% of capacity declined per month at 20
o
C(average)
Operating Temperature Range
 
  Discharge
-20~60
o
C
  Charge 
-10~60
o
C
  Storage 
-20~60
o
C
Max. Discharge Current 77
o
F(25
o
C) 
1000A(5s)
Short Circuit Current
3300A
Charge Methods: Constant Voltage Charge 77
o
F(25
o
C) 
  Cycle use
14.4-14.7V
          Maximum charging current
60A
          Temperature compensation 
-30mV/
o
C
  Standby use 
13.6-13.8V
          Temperature compensation 
-20mV/
o
C
  
Discharge Constant Current (Amperes at 77
o
F25
o
C)
 
Discharge Constant Power (Watts at 77
o
F25
o
C)
 
 
page1 of 2
 
 
(Note)The above characteristics data are average values obtained within 
three charge/discharge cycles not the mimimum values.
                    
                                             
                          
End Point
Volts/cell
5min 10min 15min 30min
1h
3h
5h
10h
20h
100h
1.60V
554
437
357
212
139
54.1
39.6
21.7
11.1
2.49
1.65V
511
412
336
203
136
52.8
38.9
21.3
11.0
2.46
1.70V
473
388
314
196
133
51.8
38.1
20.9
10.8
2.43
1.75V
443
363
294
189
129
50.6
37.3
20.4
10.7
2.40
1.80V
383
333
273
182
126
49.2
36.5
20.0
10.5
2.36
End Point
Volts/cell
5min 10min 15min 30min 45min
1h
2h
3h
5h
100h
1.60V
925
765
618
404
290
267
147
105
75.6
4.99
1.65V
876
727
598
389
283
262
144
103
75.0
4.96
1.70V
827
689
579
374
278
258
141
102
74.3
4.92
1.75V
778
648
559
359
272
252
138
100
73.8
4.88
1.80V
726
616
526
344
266
247
134
99.4
73.2
4.84