Техническая Спецификация для Finder 50.12.9.012.4000 PCB Mount Relay 12Vdc 8A 2 CO, DPDT 50.12.9.012.4000

Модели
50.12.9.012.4000
Скачать
Страница из 4
3
50 Series - Forcibly guided contacts relay 8 A
Nominal
Coil
Operating range
Resistance Rated coil
voltage
code 
consumption
U
N
U
min
U
max
R
at U
N
V
V
V
Ω
mA
5
9.005
3.8
6
35
143
6
9.006
4.5
7.2
50
120
12
9.012
9
14.4
205
58.5
24
9.024
18 28.8
820
29.3
48
9.048
36
57.6
3,280
14.4
60
9.060
45
72
5,140
11.7
110
9.110
82.5
131
17,250
6.4
125
9.125
93.7
150
22,300
5.6
DC coil data
Coil specifications
Contact specification
F 50 - Electrical life (AC) v contact current
• When switching a resistive load (DC1) having voltage and current   
values under the curve, an electrical life of ≥ 100·10
3
can be expected.
• In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
H 50 - Maximum DC1 breaking capacity
DC breaking current (A)
DC voltage (V)
- Max. permitted coil voltage.
- Min. pick-up voltage with coil at ambient temperature.
R 50 - DC coil operating range v ambient temperature
Standard coil
Alternative selection of NO and NC 
contacts to provide Forcibly guided 
(mechanically linked) contacts, in 
accordance with EN 50205 (type B).
Cycles
Resistive load - cos
ϕ = 1
Inductive load - cos
ϕ = 0.4
XII-2012, www
.finder
net.com