Техническая Спецификация для Crydom Solid State Relay El100D5-24 EL100D5-24
Модели
EL100D5-24
EL Series
• Ratings of 5A and 10A @ 3-100 VDC
• UL Recognized, CE and RoHS Compliant
• 5, 12 and 24VDC control
• Mosfet Output
PRODUCT SELECTION
Control Voltage
5A
10A
4-8 VDC
EL100D5-05
EL100D10-05
10-14 VDC
EL100D5-12
EL100D10-12
21-27 VDC
EL100D5-24
EL100D10-24
OUTPUT SPECIFICATIONS (1)(3)
Description
5A
10A
Operating Voltage Range [VDC]
3-100
3-100
Maximum Load Current [Adc] (2)
5
10
Minimum Load Current [mAdc]
150
150
Transient Overvoltage [Vpk]
600
600
Maximum Surge Current Non-Repetitive (10ms) [A]
115/120
145/150
Maximum I² t for Fusing (50/60Hz, 1/2 cycle) [A² sec]
65/60
100/95
Maximum Off-State Leakage Current @ Rated Voltage [µAdc]
100
100
Maximum On-State Resistance @ Rated Current (Rds-on)
0.04 Ohm
0.01 Ohm
Maximum On-State Voltage Drop @ Rated Current
0.2V
0.1V
INPUT SPECIFICATIONS (1)
Description
EL100Dxx-05
EL100Dxx-12
EL100Dxx-24
Control Voltage Range
4-8 VDC
10-14 VDC
21-27 VDC
Minimum Turn-On Voltage
4.0 VDC
10 VDC
21 VDC
Minimum Turn-Off Voltage
0.5 VDC
1.0 VDC
2 VDC
Typical Input Current @ nominal turn-on voltage
13.3 mA
11.7 mA
11.5 mA
Nominal Input Impedance [Ohms]
300
940
2K
Maximum Turn-On Time [msec]
1
1
1
Maximum Turn-Off Time [µsec]
300
300
300
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input to Output
2500 Vrms
Dielectric Strength, Output to Baseplate
2500 Vrms
Ambient Operating Temperature Range
-30 to 80 °C
Ambient Storage Temperature Range
-30 to 125 °C
Weight (typical)
0.5 oz (14.4g)
Terminals
3/16" input, 1/4" output QC
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) When mounted to the proper size heat sink (see derating curves)
3) Inductive loads should be diode suppressed to prevent damage to the relay.
2) When mounted to the proper size heat sink (see derating curves)
3) Inductive loads should be diode suppressed to prevent damage to the relay.