Digital Filter 
 
Background 
The digital filter function can remove unwanted 
components, such as noise, from the desired 
signal. 
The filtering only functions during continuous 
acquisition using either the Sample or Peak detect 
mode. 
The cut-off frequency range and step resolution of 
the digital filter is expressed as a fraction of the 
underlying sample rate, as shown below. 
 
Range 
Resolution 
1% ~ 49% of sample rate, Off 
1% of sample rate 
Panel Operation 
1.  Press the Acquire key. 
Acquire
 
 
2.  Press Mode on the bottom menu. 
 
 
3.  To set the acquisition mode to 
Sample or Peak Detect. 
 
 
4.  Press Digital Filter and set the 
digital frequency using the 
Variable knob. 
Turn the Variable knob fully 
anticlockwise to turn the digital 
filter off.