Backing up receiver settings
The “Receiver Setup” segment of the program 
“Firmware_Upgrade_grStudio” can be used to save all 
the data programmed in the receiver in a file on your 
computer, so that you can transfer the data set back into 
the receiver in an emergency; this eliminates the need to 
re-program the receiver using the “
Telemetry” menu, as 
would otherwise be necessary.
We recommend that you call up the “Receiver Setup” 
program from the “Firmware_Upgrade_grStudio” pro-
gram. Alternatively you can start the application directly. 
You will find the file “Receiver_Setup.exe” in the “Graup-
ner_PC-Software” folder.
Note:
If you call up “Receiver Setup” from the Firmware_Up-
grade program, ensure that the sub-program “Re-
ceiver_Setup.exe” is located in the same folder as 
the “Firmware_Upgrade_grStudio” program; see the 
screen-shot above!
For this program you need the USB interface, Order No. 
7168.6, and the interface lead, Order No. 7168.S, sup-
plied in the 
mx-16 radio control set, Order No. 33116.
Backing up receiver settings
Connecting the receiver to the PC
1. 
With the receiver switched off, connect the USB in-
terface, Order No. 
7168.6, to the socket marked “-+T” 
on the receiver using the adapter lead, Order No. 
7168.6S.
Backing up receiver settings
The connector system is polarised: note the small 
chamfers on the edges. Do not use force under any 
circumstances; the plugs should engage easily.
Adapter lead
Order No. 
7168.6A
If a central red wire is present, 
cut through it
Caution: 
If you are using the - earlier - adapter lead, Order 
No. 7168.6A, and this is fitted with a three-core 
lead, cut through the central red wire of the 
adapter lead before using it.
Now connect the USB interface to the PC or lap-
top using the USB lead supplied in the set (PC-USB 
/ mini-USB). If connected correctly, a red LED on the 
interface circuit board should light up.
The receiver should be left switched off at this point.
Receiver Setup: selecting the port
2. 
Start the program “Firmware_Upgrade_grStudio_
Ver-X.X.exe” by double-clicking on it, as described 
for updating the transmitter software (see page 41). 
(Version 1.9, which is current at the time this manu-
al went to press, starts without being installed before-
hand.)
Open the “Controller Menu” and click on “Receiver 
Setup” in the “Upgrade / Link” folder. Alternatively se-
lect the “Receiver Setup” entry under “Menu”.
A program window now appears, in which you should 
start by setting the “correct” COM port for the USB in-
terface, Order No. 
7168.6. If you are not sure of this, 
check the COM port in the “Port select” window in 
the “Controller Menu” (see earlier), and note the Com 
port number at the entry “Silicon Labs CP210x USB 
to UART Bridge”. In accordance with the previous up-
date descriptions this would be the port “COM 3”.
(If you select the wrong port, the program will alert 
you to the error.)
Reading out receiver data
3. 
Click on the “Connect” button and wait until the Sta-
tus bar below it starts to advance:
Locate the 
SET button on the receiver and hold it 
pressed in while you switch it on. After about three 
seconds the receiver’s current values will be dis-
played in the corresponding fields. If the progress bar 
is “faster than you are”, and reaches the end before 
you have switched the receiver on, the pop-up win-
dow shown here appears. In this case repeat the pro-
cedure.