Test  Items 
Test   Conditions 
Requirements 
Remark 
Drop 
resistance 
After standard charge, rest for 24 hours, 
check battery before/after dropped: 
Height: 100 cm 
Thickness of the wooden board: 
30 mm 
 
Change of voltage: 
ΔV<0.02V/ cell 
Change of internal 
impedance: 
ΔR<5mΩ/ cell 
No breakage except impact 
point for PVC sleeves 
Direction is not 
specified, Test for 3 
times 
Safety 
 
The Reverse-charge is conducted for 60 
minutes at current of 1C after 
pre-discharge at 0.2C
 
current to 0V
 
The battery shall not 
explode, but leakage & 
deformation are acceptable 
 
External Short 
Circuit 
After standard charge, short circuit the 
cell at 20+/-5 ℃  until the cell 
temperature returns to ambient 
temperature. (The resistance of the 
inter-connecting circuitry shall not 
exceed 0.1ohm.) 
The battery shall not fire 
and explode, but leakage & 
deformation are acceptable 
 
 
*REMARK 
1.Cycle life:
 
IEC61951-2/2003/7.4.1.1 
Cycles Charge 
rest  Discharge 
1 0.1C×16hrs 0 
0.25C×2hrs 20mins 
2~48 0.25C×3hrs 10mins 
0.25 C×2hrs 20mins 
49 0.25 
C×3hrs 10mins 
0.25C to 1.0V/cell 
50 0.1 
C×16hrs 
1~4hrs 
0.20C to 1.0V/cell 
Repeat 1 to 50 cycles ,until the discharge time of any 50
th
 cycle is less than 3hrs   
 
2.COSMETIC 
Batteries should be without any flaw、stain、discoloration or leakage and deformation.   
 
3.WARNING: 
3.1 Do not dispose of cell into fire or dismantled under any condition. 
3.2 Do not mix different cell types and capacities in the same battery assembly.   
3.3 Charge and discharge under specified ambient temperature.
3.4 Short circuit leading to cell venting must be avoided. 
3.5 Never solder onto cell directly. 
3.6 Cell reversal should be avoided.