GSM Alarm & Telemetry systems
1. XXXXXXXXXXXX X XXXX XXX X XXXXXXXX ---- - SMS_ 1
No.:
Shows the number of the choosen action in this part of the connection
settings. All settings (1 or 0 or X) beside this number in the same line
are dedicated for this action.
PP:
Means „Power Pin“. Here you can choose whether the system should
react on the change of the current powering mode (power supply or ac-
cumulator).
1 : Powerd by regular power supply
0 : Powered over the accumulator(e.g. in case of power loss)
X : The value will be ignored and is not neccessary for this action
D_In:
Means the digital inputs. In the row you have the input 1 up to 12. If you
have versions with only 4 digital inputs on the hardware side, only set-
tings of the first 4 digital are neccesary for you. Please ignore the other
setting possibilities of the last 8 inputs (value X).
1 : The input is not pulled to ground
0 : The input is pulled to ground
X : The value will be ignored and is not neccessary for this action
A_In:
This means the analoge inputs.
1 : Meassurement is inside the right tolerance
0 : Meassurement is outside the right tolerance(above or under)
X : The value will be ignored and is not neccessary for this action
Zeit:
This means the 3 possible time frames.
1 : The setted time frame is important for this action
0 : The setted time frame is not important for this action
X : The time frame will be ignored and is not neccessary for this
action
GSM:
This means the connection to the choosen provider.
1 : The value is important for the action
0 : The value is not important for the action
X : The value will be ignored and is not neccessary for this action