ICD3Err0046: An error occurred while trying to read the stopwatch count. The 
stopwatch count may not be accurate.
ICD3Err0052: The current ICD 3 hardware version %x, is out of date. This version 
of MPLAB IDE will support only version %x or higher.
Did you click Cancel when asked to download the latest firmware? If so, you will need 
to download it now. Select Debugger>SettingsConfiguration tab, and click Manual 
Download
. Select the highest number .jam file and click Open.
If you cannot find any files to download or if this does not work (corrupted file), you will 
need to get the latest version of MPLAB IDE and install it. Find the latest MPLAB IDE 
at www.microchip.com.
ICD3Err0053: Unable to get ICD 3 protocol versions.
ICD3Err0054: MPLAB IDE's ICD 3 protocol definitions are out of date. You must 
upgrade MPLAB IDE to continue.
Find the latest MPLAB IDE at www.microchip.com.
ICD3Err0055: Unable to set firmware suite version.
ICD3Err0056: Unable to get voltages from ICD 3.
ICD3Err0057: Self-test could not be completed.
Ensure that you are using the ICD3 self-test board. Also, see 
Section 7.3.2 “Debugger-to-Target Communication Error Actions”.
ICD3Err0063: Test interface clock write failure. Please ensure that the tester is 
properly connected.
ICD3Err0064: Test interface data write failure.
ICD3Err0065: Test interface clock read failure.
ICD3Err0066: Test interface data read failure.
Clock/data not being output from the debugger. Check your connections and try again.
ICD3Err0067: Failed to set/clear software breakpoint.
Reprogram and try again.
ICD3Err0068: Failed while writing to boot FLASH memory.
ICD3Err0069: Failed while reading boot FLASH memory.
ICD3Err0070: Failed while writing peripheral memory.
ICD3Err0071: Failed while reading peripheral memory.
ICD3Err0072: Unable to send freeze peripheral information.
ICD3Err0073: Device is code protected.
The device on which you are attempting to operate (read, program, blank check or 
verify) is code protected, i.e., the code cannot be read or modified. Check your 
Configuration bits setting for code protection.
To disable code protection, set or clear the appropriate Configuration bits in code or in 
the Configuration Bits window (Configure>Configuration Bits), according to the device 
data sheet. Then erase and reprogram the entire device.
ICD3Err0082: Test interface LVP failure.
ICD3Err0083: Test interface MCLR failure