ICD3Err0046: An error occurred while trying to read the stopwatch count. The
stopwatch count may not be accurate.
stopwatch count may not be accurate.
ICD3Err0047: Bootloader download failed.
See Section 7.3.3 “Debugger-to-PC Communication Error Actions”.
See Section 7.3.3 “Debugger-to-PC Communication Error Actions”.
ICD3Err0052: The current ICD 3 hardware version %x, is out of date. This version
of MPLAB IDE will support only version %x or higher.
of MPLAB IDE will support only version %x or higher.
Did you click Cancel when asked to download the latest firmware? If so, you will need
to download it now. Select Debugger>Settings, Configuration tab, and click Manual
Download. Select the highest number .jam file and click Open.
to download it now. Select Debugger>Settings, Configuration tab, and click Manual
Download. Select the highest number .jam file and click Open.
If you cannot find any files to download or if this does not work (corrupted file), you will
need to get the latest version of MPLAB IDE and install it. Find the latest MPLAB IDE
at www.microchip.com.
need to get the latest version of MPLAB IDE and install it. Find the latest MPLAB IDE
at www.microchip.com.
ICD3Err0053: Unable to get ICD 3 protocol versions.
ICD3Err0054: MPLAB IDE's ICD 3 protocol definitions are out of date. You must
upgrade MPLAB IDE to continue.
upgrade MPLAB IDE to continue.
Find the latest MPLAB IDE at www.microchip.com.
ICD3Err0055: Unable to set firmware suite version.
ICD3Err0056: Unable to get voltages from ICD 3.
ICD3Err0056: Unable to get voltages from ICD 3.
ICD3Err0057: Self-test could not be completed.
Ensure that you are using the ICD3 self-test board. Also, see
Section 7.3.2 “Debugger-to-Target Communication Error Actions”.
Section 7.3.2 “Debugger-to-Target Communication Error Actions”.
ICD3Err0063: Test interface clock write failure. Please ensure that the tester is
properly connected.
ICD3Err0064: Test interface data write failure.
ICD3Err0065: Test interface clock read failure.
ICD3Err0066: Test interface data read failure.
properly connected.
ICD3Err0064: Test interface data write failure.
ICD3Err0065: Test interface clock read failure.
ICD3Err0066: Test interface data read failure.
Clock/data not being output from the debugger. Check your connections and try again.
ICD3Err0067: Failed to set/clear software breakpoint.
Reprogram and try again.
ICD3Err0068: Failed while writing to boot FLASH memory.
ICD3Err0069: Failed while reading boot FLASH memory.
ICD3Err0070: Failed while writing peripheral memory.
ICD3Err0071: Failed while reading peripheral memory.
ICD3Err0069: Failed while reading boot FLASH memory.
ICD3Err0070: Failed while writing peripheral memory.
ICD3Err0071: Failed while reading peripheral memory.
ICD3Err0072: Unable to send freeze peripheral information.
ICD3Err0073: Device is code protected.
The device on which you are attempting to operate (read, program, blank check or
verify) is code protected, i.e., the code cannot be read or modified. Check your
Configuration bits setting for code protection.
verify) is code protected, i.e., the code cannot be read or modified. Check your
Configuration bits setting for code protection.
To disable code protection, set or clear the appropriate Configuration bits in code or in
the Configuration Bits window (Configure>Configuration Bits), according to the device
data sheet. Then erase and reprogram the entire device.
the Configuration Bits window (Configure>Configuration Bits), according to the device
data sheet. Then erase and reprogram the entire device.
ICD3Err0082: Test interface LVP failure.
ICD3Err0083: Test interface MCLR failure