bit 7-3
FLTSRC<4:0>: Fault Control Signal Source Select bits for PWM Generator #
(
11111 = Reserved



01011 = Reserved
01010 = Comparator 3
01001 = Comparator 2
01000 = Comparator 1
00111 = Reserved
00110 = Fault 7
00101 = Fault 6
00100 = Fault 5
00011 = Fault 4
00010 = Fault 3
00001 = Fault 2
00000 = Fault 1
bit 2
FLTPOL: Fault Polarity bit for PWM Generator #
1 = The selected Fault source is active-low
0 = The selected Fault source is active-high
bit 1-0
FLTMOD<1:0>: Fault Mode bits for PWM Generator #
11 = Fault input is disabled
10 = Reserved
01 = The selected Fault source forces PWMxH, PWMxL pins to FLTDAT values (cycle)
00 = The selected Fault source forces PWMxH, PWMxL pins to FLTDAT values (latched condition)
REGISTER 16-21: FCLCONx: PWMx FAULT CURRENT-LIMIT CONTROL REGISTER (CONTINUED)
Note 1: These bits should be changed only when PTEN = 0. Changing the clock selection during operation will 
yield unpredictable results.
2: When Independent Fault mode is enabled (IFLTMOD = 1) and Fault 1 is used for Fault mode 
(FLTSRC<4:0> = 01000), the Current-Limit Control Source Select bits (CLSRC<4:0>) should be set to an 
unused current-limit source to prevent the current-limit source from disabling both the PWMxH and 
PWMxL outputs.
3: When Independent Fault mode is enabled (IFLTMOD = 1) and Fault 1 is used for Current-Limit mode 
(CLSRC<4:0> = 01000), the Fault Control Source Select bits (FLTSRC<4:0>) should be set to an unused 
Fault source to prevent Fault 1 from disabling both the PWMxL and PWMxH outputs.