Техническая Спецификация для Microchip Technology MA240017
PIC24F16KA102 FAMILY
DS39927C-page 232
2008-2011 Microchip Technology Inc.
FIGURE 29-5:
EXTERNAL CLOCK TIMING
OSCI
CLKO
Q4
Q1
Q2
Q3
Q4
Q1
OS20
OS25
OS30
OS30
OS40
OS41
OS31
OS31
Q1
Q2
Q3
Q4
Q2
Q3
TABLE 29-19: EXTERNAL CLOCK TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 1.8 to 3.6V (unless otherwise stated)
Operating temperature
Operating temperature
-40°C
T
A
+85°C for Industrial
-40°C
T
A
+125°C for Extended
Param
No.
Sym
Characteristic
Min
Typ
(
)
Max
Units
Conditions
OS10 F
OSC
External CLKI Frequency
(External clocks allowed
only in EC mode)
(External clocks allowed
only in EC mode)
(
)
DC
4
—
—
—
32
8
MHz
MHz
MHz
EC
ECPLL
ECPLL
Oscillator Frequency
)
0.2
4
4
4
31
—
—
—
—
—
—
—
4
25
8
33
MHz
MHz
MHz
MHz
MHz
kHz
XT
HS
HSPLL
SOSC
HS
HSPLL
SOSC
OS20 T
OSC
T
OSC
= 1/F
OSC
—
—
—
—
See Parameter
for F
OSC
value
OS25 T
CY
Instruction Cycle Time
(
62.5
—
DC
ns
OS30 TosL,
TosH
External Clock in (OSCI)
High or Low Time
High or Low Time
0.45 x T
OSC
—
—
ns
EC
OS31 TosR,
TosF
External Clock in (OSCI)
Rise or Fall Time
Rise or Fall Time
—
—
20
ns
EC
OS40 TckR CLKO Rise Time
(
)
—
6
10
ns
OS41 TckF
CLKO Fall Time
—
6
10
ns
Note 1:
Data in “Typ” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance only
and are not tested.
and are not tested.
2:
Refer to
3:
Instruction cycle period (T
CY
) equals two times the input oscillator time base period. All specified values are
based on characterization data for that particular oscillator type under standard operating conditions with
the device executing code. Exceeding these specified limits may result in an unstable oscillator operation
and/or higher than expected current consumption. All devices are tested to operate at “Min.” values with an
external clock applied to the OSCI/CLKI pin. When an external clock input is used, the “Max.” cycle time
limit is “DC” (no clock) for all devices.
the device executing code. Exceeding these specified limits may result in an unstable oscillator operation
and/or higher than expected current consumption. All devices are tested to operate at “Min.” values with an
external clock applied to the OSCI/CLKI pin. When an external clock input is used, the “Max.” cycle time
limit is “DC” (no clock) for all devices.
4:
Measurements are taken in EC mode. The CLKO signal is measured on the OSCO pin. CLKO is low for the
Q1-Q2 period (1/2 T
Q1-Q2 period (1/2 T
CY
) and high for the Q3-Q4 period (1/2 T
CY
).