dsPIC33FJ16(GP/MC)101/102 AND dsPIC33FJ32(GP/MC)101/102/104
 
TABLE 26-46: I2Cx BUS DATA TIMING REQUIREMENTS (SLAVE MODE)
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature
-40°C 
 T
A
 
 +85°C for Industrial
-40°C 
 T
A
 
 +125°C for Extended
Param. Symbol
Characteristic
Min
Max
Units
Conditions
IS10
T
LO
:
SCL
Clock Low Time
100 kHz mode
4.7
s
Device must operate at a 
minimum of 1.5 MHz
400 kHz mode
1.3
s
Device must operate at a 
minimum of 10 MHz
1 MHz mode
0.5
s
IS11
T
HI
:
SCL
Clock High Time
100 kHz mode
4.0
s
Device must operate at a 
minimum of 1.5 MHz
400 kHz mode
0.6
s
Device must operate at a 
minimum of 10 MHz
1 MHz mode
0.5
s
IS20
T
F
:
SCL
SDAx and SCLx
Fall Time
100 kHz mode 
300
ns
C
B
 is specified to be from
10 to 400 pF
400 kHz mode
20 + 0.1 C
B
300
ns
1 MHz mode
100
ns
IS21
T
R
:
SCL
SDAx and SCLx
Rise Time
100 kHz mode 
1000
ns
C
B
 is specified to be from
10 to 400 pF
400 kHz mode
20 + 0.1 C
B
300
ns
1 MHz mode
300
ns
IS25
T
SU
:
DAT
Data Input
Setup Time
100 kHz mode
250
ns
400 kHz mode
100
ns
1 MHz mode
100
ns
IS26
T
HD
:
DAT
Data Input
Hold Time
100 kHz mode 
0
s
400 kHz mode
0
0.9
s
1 MHz mode
0
0.3
s
IS30
T
SU
:
STA
Start Condition
Setup Time
100 kHz mode
4.7
s
Only relevant for Repeated 
Start condition
400 kHz mode
0.6
s
1 MHz mode
0.25
s
IS31
T
HD
:
STA
Start Condition 
Hold Time 
100 kHz mode
4.0
s
After this period, the first 
clock pulse is generated
400 kHz mode
0.6
s
1 MHz mode
0.25
s
IS33
T
SU
:
STO
Stop Condition 
Setup Time
100 kHz mode
4.7
s
400 kHz mode
0.6
s
1 MHz mode
0.6
s
IS34
T
HD
:
STO
Stop Condition
Hold Time
100 kHz mode 
4000
ns
400 kHz mode
600
ns
1 MHz mode
250
ns
IS40
T
AA
:
SCL
Output Valid 
from Clock
100 kHz mode
0
3500
ns
400 kHz mode
0
1000
ns
1 MHz mode
0
350
ns
IS45
T
BF
:
SDA
Bus Free Time
100 kHz mode
4.7
s
Time the bus must be free 
before a new transmission 
can start
400 kHz mode
1.3
s
1 MHz mode
0.5
s
IS50
C
B
Bus Capacitive Loading
 400
pF 
Note 1: