REGISTER 21-3:
SSPxSTAT: MSSPx STATUS REGISTER (I
2
C™ MODE) 
R/W-0
R/W-0
R-0
R-0
R-0
R-0
R-0
R-0
SMP
CKE
D/A
P
(
S
(
)
R/W
)
UA
BF
bit 7
bit 0
Legend:
R = Readable bit
W = Writable bit
U = Unimplemented bit, read as ‘0’
-n = Value at POR
‘1’ = Bit is set
‘0’ = Bit is cleared
x = Bit is unknown
bit 7
SMP: 
Slew Rate Control bit
In Master or Slave mode: 
1
 = Slew rate control is disabled for Standard Speed mode (100 kHz and 1 MHz) 
0
 = Slew rate control is enabled for High-Speed mode (400 kHz)
bit 6
CKE:
 SMBus Select bit
In Master or Slave mode:
1
 = Enable SMBus-specific inputs 
0
 = Disable SMBus-specific inputs 
bit 5
D/A:
 Data/Address bit 
In Master mode:
Reserved.
In Slave mode:
1
 = Indicates that the last byte received or transmitted was data
0
 = Indicates that the last byte received or transmitted was an address
bit 4
P:
 Stop bit
1
 = Indicates that a Stop bit has been detected last
0
 = Stop bit was not detected last
bit 3
S:
 Start bit
(
)
1
 = Indicates that a Start bit has been detected last
0
 = Start bit was not detected last
bit 2
R/W:
 Read/Write Information bit
(
In Slave mode:
1
 = Read
0
 = Write
In Master mode:
1
 = Transmit is in progress
0
 = Transmit is not in progress
bit 1
UA:
 Update Address bit (10-Bit Slave mode only)
1
 = Indicates that the user needs to update the address in the SSPxADD register 
0
 = Address does not need to be updated
bit 0
BF:
 Buffer Full Status bit
In Transmit mode: 
1
 = SSPxBUF is full 
0
 = SSPxBUF is empty
In Receive mode:
1
 = SSPxBUF is full (does not include the ACK and Stop bits)
0
 = SSPxBUF is empty (does not include the ACK and Stop bits)
Note 1:
This bit is cleared on Reset and when SSPEN is cleared.
2:
This bit holds the R/W bit information following the last address match. This bit is only valid from the 
address match to the next Start bit, Stop bit or not ACK bit.
3:
ORing this bit with SEN, RSEN, PEN, RCEN or ACKEN will indicate if the MSSPx is in Active mode.