Техническая Спецификация для Conrad Energy Button cell ZA10 Zinc air ZA10 90 mAh 1.4 V 6 pc(s) 650493
Модели
650493
Zinc Air Battery
A10
Z
SPECIFICATIONS:
Nominal Voltage: 1.4V
Rated Capacity:
Rated Capacity:
90mAh
at 3000
Ω
to 0.9V
at 25℃ RH 60%
Average weight 0.31g
Volume: 0.08cm
at 25℃ RH 60%
Average weight 0.31g
Volume: 0.08cm
3
Terminals: FLAT
Operating Temp. 0℃ to
Range: 50℃
Impedance:
Operating Temp. 0℃ to
Range: 50℃
Impedance:
≤ 8Ω
at AC 1000Hz
Limiting current: 3mA
@1.1V
IEC: PR70
@1.1V
IEC: PR70
DISCHARGE CHARACTERISTICS AT 3K
Ω 25℃ RH 60%
(Discharged 24 hours /day)
0 34 68 102
136 170 204 238
Service life (h)
This data sheet is subject to change without prior notice.
Contact us for the latest information. Contents here do not
constitute a warranty.
July, 2007
Z
B,
Z
E
H
T
H
T
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0
Voltage(v)