OPERATING INSTRUCTIONS
VERSION 01/13
AM-49X27/KONTROLL
PANEL METER
ITEM NO.: 10 35 50
INTENDED USE
This product is designed for the assembly of simple testers and battery monitoring units 
of all sorts. External wiring may be necessary, depending on application. The colour scale 
(traffic light scale) gives a quick overview as a control indicator. Only in integrated status the
product may be put into operation. The suitable regulations are to be observed. The scale 
needle can be adjusted precisely with the front screw. The product is intended for DC current 
measurements only. The maximum permitted current rating is 270 µA (full-scale deflection). 
Observe the technical data for this!
For safety and approval purposes, you must not rebuild and/or modify this product. If you use 
the product for purposes other than those described above, the product may be damaged. 
In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc.
Read the instructions carefully and keep them. Make this product available to third parties 
only together with its operating instructions.
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
DELIVERY CONTENT
•  Meter
•  Operating instructions
SAFETY INSTRUCTIONS
Read the operating instructions carefully and especially observe the safety 
information. If you do not follow the safety instructions and information 
on proper handling in this manual, we assume no liability for any resulting 
personal injury or damage to property. Such cases will invalidate the 
warranty/guarantee.
a) Persons / Product
•  The device must not be used in damp interiors or outdoors in the open air.
•  Be sure not to exceed the maximum permissible measurement range. You must 
observe the technical data.
•  Be especially cautious in dealing with voltage >35 V/DC. Already at this voltage 
you can get a life-threatening electric shock when touching electric lines.
•  De-energise the electric system before installing the measuring instrument.
•  The device is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. These may become 
dangerous playing material for children.
•  Protect the product from extreme temperatures, direct sunlight, strong jolts, high 
humidity, moisture, flammable gases, vapours and solvents.
•  Do not place the product under any mechanical stress.
•  If it is no longer possible to operate the product safely, take it out of operation and 
protect it from any accidental use. Safe operation can no longer be guaranteed if 
the product:
 - is visibly damaged, 
 - is no longer working properly, 
 - has been stored for extended periods in poor ambient conditions or 
 - has been subjected to any serious transport-related stresses.
•  Please handle the product carefully. Jolts, impacts or a fall even from a low height 
can damage the product.
•  Also observe the safety and operating instructions of any other devices which are 
connected to the product.
b) Miscellaneous
•  Consult an expert when in doubt about operation, safety or connection of the 
device.
•  Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
 Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7  
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2013 by Voltcraft®
If you are not sure about the correct connection or use, or if questions arise which are not
covered by these operating instructions, please do not hesitate to contact our technical 
support or another qualified specialist.
Voltcraft®, Lindenweg 15, D-92242 Hirschau, Tel. +49 180/586 582 7.
INSTALLATION
Assembly and installation may only be carried out by a specialist, who is 
familiar with the relevant regulations and the ensuing risks.
Mount the product on a suitable, rectangular opening. Carefully attach the measuring 
instrument. You can get the corresponding dimensions (in mm) from the following sketch. 
50.0
55.0
4.0
18.2
8.0
18.2
8.5
5.0
14.0
47.5
28.0
18.0
+
-
CONNECTION
In order to ensure a correct start of operation, you should read these 
operating instructions including the safety instructions thoroughly and 
attentively before using the device.
Do not connect when the wires are live.
Connection of the panel meter has to be done in series connection. Connect the panel meter 
to both + and - solder terminals on the back. You must observe the correct polarity to avoid 
damaging the product.
DISPOSAL
Electronic devices are recyclable waste and must not be disposed of in the 
household waste.
At the end of its service life, dispose of the product according to the relevant 
statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
TECHNICAL DATA
Measurement range  
(full-scale deflection) ......................  270  µA
Internal resistance .........................  1.66 kΩ
Accuracy class .................................5
Movement ......................................  Moving  coil
Installation dimensions ..................  50 x 28 mm
Electrical connection ......................  Soldered  connection
Operating conditions ......................  -25 to +55 °C, 20 – 95 % RH (non-condensing)
Storage conditions .........................  -40 to +70 °C, 20 – 95 % RH (non-condensing)
Weight ...........................................  approx. 17 g