2  Fluke Corporation   Fluke 721 Precision Pressure Calibrator
Low pressure sensor
High pressure sensor
Model
Description
Range sensor 1
Resolution  
sensor 1
Accuracy
sensor 1
Range sensor 2
Resolution 
sensor 2
Accuracy 
sensor 2
Fluke-721-1601 Dual Sensor Pressure Cali-
brator, 16 PSIG, 100 PSIG
-14 psi to +16 psi 
-0.97 bar to 1.1 bar
0.001 psi, 
0.0001 bar
0.025 % of 
full scale
-12  psi  to  +100  psi           
-0.83 bar to 6.9 bar
0.01 psi
0.0001 bar
0.025 % of 
full scale
Fluke-721-1603  Dual Sensor Pressure Cali-
brator, 16 PSIG, 300 PSIG
-12  psi  to  +300  psi           
-0.83 bar to 20 bar
0.01 psi
0.001 bar
Fluke-721-1605  Dual Sensor Pressure Cali-
brator, 16 PSIG, 500 PSIG
-12  psi  to  +500  psi        
-0.83 bar to 34.5 bar
0.01 psi
0.001 bar
Fluke-721-1610  Dual Sensor Pressure Cali-
brator, 16 PSIG, 1000 PSIG
0 psi to +1000 psi         
0.00 bar to 69 bar
0.1 psi
0.001 bar
Fluke-721-1615 Dual Sensor Pressure Cali-
brator, 16 PSIG, 1500 PSIG
0 psi to +1500 psi         
0.00 bar to 103.4 bar
0.1 psi
0.001 bar
Fluke-721-1630 Dual Sensor Pressure Cali-
brator, 16 PSIG, 3000 PSIG
0 psi to +3000 psi         
0.00 bar to 200 bar
0.1 psi
0.01 bar
Fluke-721-1650 Dual Sensor Pressure Cali-
brator, 16 PSIG, 5000 PSIG
0  psi  to  +5000  psi              
0.00 bar to 345 bar
0.1 psi
0.01 bar
0.035 % of 
full scale
Fluke-721-3601 Dual Sensor Pressure Cali-
brator, 36 PSIG, 100 PSIG
-14 psi to +36 psi   
-0.97 bar to 2.48 bar
-12 to +100 psi           
-0.83 bar to 6.9 bar
.01 psi
0.0001 bar
0.025 % of 
full scale
Fluke-721-3603 Dual Sensor Pressure Cali-
brator, 36 PSIG, 300 PSIG
-12  psi  to  +300  psi           
-0.83 bar to 20 bar
0.01 psi
0.001 bar
Fluke-721-3605 Dual Sensor Pressure Cali-
brator, 36 PSIG, 500 PSIG
-12  psi  to  +500  psi        
-0.83 bar to 34.5 bar
0.01 psi
0.001 bar
Fluke-721-3610 Dual Sensor Pressure Cali-
brator, 36 PSIG, 1000 PSIG
0 psi to +1000 psi         
0.00 bar to 69 bar
0.1 psi
0.001 bar
Fluke-721-3615 Dual Sensor Pressure Cali-
brator, 36 PSIG, 1500 PSIG
0 psi to +1500 psi         
0.00 bar to 103.4 bar
0.1 psi
0.01 bar
Fluke-721-3630 Dual Sensor Pressure Cali-
brator, 36 PSIG, 3000 PSIG
0 psi to +3000 psi         
0.00 bar to 200 bar
0.1 psi
0.01 bar
Fluke-721-3650 Dual Sensor Pressure Cali-
brator, 36 PSIG, 5000 PSIG
0  psi  to  +5000  psi              
0.00 bar to 345 bar
0.1 psi
0.01 bar
0.035 % of 
full scale
Temperature effect
No effect on accuracy on all functions from 15 °C to 35 °C
Add ± 0.002  % F.S./°C for temps outside of 15 °C to 35 °C
General specifications
Instrument setup recall
Last used on power-up
Environmental
Operating temperature -10 °C 
to +50 °C
Storage temperature (without 
batteries) -20 °C to +60 °C
Altitude
2,000 meters
Ingress protection
IP-40
Power requirements
6.0 v dc
Battery life
>35 hours, typical usage
Batteries required
(4) Standard AA cells
Dimentions (HxWxD)
7.9” X 4.3” X 2.3” (20 cm X  
11 cm X 5.8 cm)
Weight
03539 kg (1 lb 3 oz)
Connectors/ports pressure Two, 1/8 in NPT, 700P Series 
Pressure Module; RTD Probe
Specifications 1-year
Electrical and temperature measurement 1-year
Function
Range
Resolution
Accuracy
mA measure 
0 to 24 mA
0.001 mA
±0.015% of rdg 
±0.002mA
VDC  measure 
0 to 30 VDC
0.001V
±0.015% of rdg 
±0.002V
*Temperature 
measure (RTD/
Ohms)
 -40 °C to 150 °C  
(-40 °F to 302 °F)
0.01 °C, 0.01 °F
 ±0.015% of rdg 
±0.02 ohms; 
±0.1°C  (±0.2°F)
±0.25 degC (±0.45 
degF) combined 
uncertainty when 
using 720 RTD 
probe accessory
Loop power supply 24V
N/A
24 mA @ 24V
*Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe 
available as an accessory