Техническая Спецификация для Aerotec 2009534

Скачать
Страница из 7
The Assembly in Individual Steps: 
 
Fix the pressure gauge to the suction line. Ensure that 
the pressure gauge can be easily read. Then screw 
the valve on to the line below. The nipple must now be 
connected to the valve, after that, fit the connection in 
to the line: 
 
 
 
Both sides of the water trap must now be fitted with a 
nipple. After this, fasten each of the compressed air 
feed and the valve to a nipple: 
 
 
      
 
 
Now lay the tank on a scratch-free surface with the 
retaining lugs uppermost and screw the pre-
assembled water trap in to the free bore of the 
suction line. Then screw the connecting tube to the 
side bore of the tank. 
 
 
Then align the pressure gauge and the suction line: 
 
 
 
 
Now screw the nipple in to the lower tank opening and 
after that, the sand regulator. To this, there follows an 
additional nipple. Now screw the sand outlet to the 
nipple: 
 
 
 
 
Now assemble the blasting grip: Fix the nozzle of 
choice in the jaws, screw on a nipple and firmly 
connect the hose with the tank and the blasting grip 
and secure each with the clamps. Pay special 
attention to a tight fit as a pressure of up to 8.5 bar 
can arise. Lack of tight fit can lead to serious injuries! 
 
Finally, the handle and the wheel set must be fitted in 
accordance with Chapter 1. 
 
Filling with Blasting Media: 
 
Wherever possible, only use blasting media of silicon, 
carbide or aluminium oxide. Sand, due to its natural 
constituents can lead to blockages. In addition, sands 
wear out the machine more and are less effective in 
their application. 
The blasting media must be completely dry otherwise 
this can also lead to blockages. 
 
Before the filling process, disconnect the machine 
from the compressed air supply and completely 
relieve the pressure. Ensure that the pressure gauge 
indicates 0!! 
 
Then remove the tank cover, put the funnel in the 
filling aperture and half fill the tank, maximum, 
however, to ¾. The higher the humidity in the 
atmosphere, the less the tank should be filled! 
 
Close the tank after the filling. 
 
Close the shut-off valve and open the valve after it 
has been ensured that the blasting gun is locked at 
the nozzle. 
 
Then connect the machine to the compressed air 
supply and switch it on. 
 
Always wear protective clothing! 
 
9. Safety Advice for Operators  
 
Only use the equipment after you have carefully read 
the operating instructions.  
 
Observe all safety advice given in the operating 
instructions.  
 
 
Behave responsibly towards other people.