Atmel-11100G-ATARM-SAM4S-Datasheet_27-May-14
When the gain, offset or differential input parameters of the analog cell change between two channels, the analog
cell may need a specific settling time before starting the tracking phase. In that case, the controller automatically
waits during the settling time defined in the ADC_MR. Obviously, if the ANACH option is not set, this time is
unused.
Warning:
Warning:
No input buffer amplifier to isolate the source is included in the ADC. This must be taken into
consideration to program a precise value in the TRACKTIM field. See the product “ADC Characteristics” section.
42.6.11 Automatic Calibration
The ADC features an automatic calibration (AUTOCALIB) mode for gain errors (calibration).
The automatic calibration sequence can be started at any time writing to '1' the AUTOCAL bit of the ADC Control
The automatic calibration sequence can be started at any time writing to '1' the AUTOCAL bit of the ADC Control
Register. The automatic calibration sequence requires a software reset command (SWRST in the ADC_CR) prior
to write AUTOCAL bit. The end of calibration sequence is given by the EOCAL bit in the interrupt status register
(ADC_ISR), and an interrupt is generated if EOCAL interrupt has been enabled (ADC_IER).
The calibration sequence will perform an automatic calibration on all enabled channels. The channels required for
The calibration sequence will perform an automatic calibration on all enabled channels. The channels required for
conversion do not need to be all enabled during the calibration process if they are programmed with the same
gain. Only channels with different gain settings need to be enabled. The gain settings of all enabled channels must
be set before starting the AUTOCALIB sequence. If the gain settings (ADC_CGR and ADC_COR) for a given
channel are changed, the AUTOCALIB sequence must then be started again.
The calibration data (on one or more enabled channels) is stored in the internal ADC memory.
Then, when a new conversion is started (on one or more enabled channels), the converted value (in ADC_LCDR
The calibration data (on one or more enabled channels) is stored in the internal ADC memory.
Then, when a new conversion is started (on one or more enabled channels), the converted value (in ADC_LCDR
or ADC_CDRx) is a calibrated value.
Autocalibration is for settings, not for channels. Therefore, if a specific combination of gain has been already
Autocalibration is for settings, not for channels. Therefore, if a specific combination of gain has been already
calibrated, and a new channel with the same settings is enabled after the initial calibration, there is no need to
restart a calibration. If different enabled channels have different gain settings, the corresponding channels must be
enabled before starting the calibration.
If a software reset is performed (SWRST bit in ADC_CR) or after power up (or wake-up from Backup mode), the
If a software reset is performed (SWRST bit in ADC_CR) or after power up (or wake-up from Backup mode), the
calibration data in the ADC memory is lost.
Changing the ADC running mode (in ADC_CR) does not affect the calibration data.
Changing the ADC reference voltage (ADVREF pin) requires a new calibration sequence.
For calibration time, gain error after calibration, refer to the 12-bit ADC electrical characteristics section of the
Changing the ADC running mode (in ADC_CR) does not affect the calibration data.
Changing the ADC reference voltage (ADVREF pin) requires a new calibration sequence.
For calibration time, gain error after calibration, refer to the 12-bit ADC electrical characteristics section of the
product.
42.6.12 Buffer Structure
The PDC read channel is triggered each time a new data is stored in ADC_LCDR. The same structure of data is
repeatedly stored in ADC_LCDR each time a trigger event occurs. Depending on user mode of operation
(ADC_MR, ADC_CHSR, ADC_SEQR1, ADC_SEQR2) the structure differs. Each data read to PDC buffer, carried
on a half-word (16-bit), consists of last converted data right aligned and when TAG is set in ADC_EMR, the four
most significant bits are carrying the channel number thus allowing an easier post-processing in the PDC buffer or
better checking the PDC buffer integrity.
42.6.13 Fault Output
The ADC Controller internal fault output is directly connected to PWM fault input. Fault output may be asserted
according to the configuration of ADC_EMR (Extended Mode Register) and ADC_CWR (Compare Window
Register) and converted values. When the Compare occurs, the ADC fault output generates a pulse of one Master
Clock Cycle to the PWM fault input. This fault line can be enabled or disabled within PWM. Should it be activated
and asserted by the ADC Controller, the PWM outputs are immediately placed in a safe state (pure combinational