Electrical Parameter
 
Data Sheet
35
V1.4, 2014-05
 
 provides the active current consumption of some modules operating at 5 V
power supply at 25
°
 C. The typical values shown are used as a reference guide on the
current consumption when these modules are enabled.
Table 15
Typical Active Current Consumption
1)
1) Not subject to production test, verified by design/characterisation.
Active Current 
Consumption
Symbol
Limit 
Values
Unit
Test Condition
Typ.
Baseload current
I
CPUDDC
5.04
mA
Modules including Core, SCU, 
PORT, memories, ANATOP
2)
2) Baseload current is measured with device running in user mode, MCLK=PCLK=32 MHz, with an endless loop
in the flash memory. The clock to the modules stated in CGATSTAT0 are gated.
VADC and SHS
I
ADCDDC
3.4
mA
Set CGATCLR0.VADC to 1
3)
3) Active current is measured with: module enabled, MCLK=32 MHz, running in auto-scan conversion mode
USIC0
I
USIC0DDC
0.87
mA
Set CGATCLR0.USIC0 to 1
4)
4) Active current is measured with: module enabled, alternating messages sent to PC at 57.6kbaud every 200ms 
CCU40
I
CCU40DDC
0.94
mA
Set CGATCLR0.CCU40 to 1
5)
5) Active current is measured with: module enabled, MCLK=PCLK=32 MHz, 1 CCU4 slice for PWM switching
from 1500Hz and 1000Hz at regular intervals, 1 CCU4 slice in capture mode for reading period and duty cycle
WDT
I
WDTDDC
0.03
mA
Set CGATCLR0.WDT to 1
6)
6) Active current is measured with: module enabled, MCLK=32 MHz, time-out mode; WLB = 0, WUB =
0x00008000; WDT serviced every 1s
RTC
I
RTCDDC
0.01
mA
Set CGATCLR0.RTC to 1
7)
7) Active current is measured with: module enabled, MCLK=32 MHz, Periodic interrupt enabled
Subject to Agreement on the Use of Product Information