Техническая Спецификация для Atmel Evaluation Kit AT91SAM9M10-G45-EK AT91SAM9M10-G45-EK

Модели
AT91SAM9M10-G45-EK
Скачать
Страница из 1361
 646
SAM9M10 [DATASHEET]
6355F–ATARM–12-Mar-13
 
34.6.11.2
WAVSEL = 10
When WAVSEL = 10, the value of TC_CV is incremented from 0 to the value of RC, then automatically reset on a
RC Compare. Once the value of TC_CV has been reset, it is then incremented and so on. See 
It is important to note that TC_CV can be reset at any time by an external event or a software trigger if both are pro-
grammed correctly. See 
In addition, RC Compare can stop the counter clock (CPCSTOP = 1 in TC_CMR) and/or disable the counter clock
(CPCDIS = 1 in TC_CMR).
Figure  34-9.
WAVSEL = 10 Without Trigger
Figure  34-10.
WAVSEL = 10 With Trigger
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter cleared by compare match with RC
0xFFFF
Waveform Examples
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter cleared by compare match with RC
0xFFFF
Waveform Examples
Counter cleared by trigger