Техническая Спецификация для Atmel Evaluation Kit for AT32uC3A0512, 32-Bit AVR Microcontroller Atmel ATEVK1105 ATEVK1105

Модели
ATEVK1105
Скачать
Страница из 826
81
AT32UC3A
13.6.11
BOD Control
BOD Level register
Register name
BOD
Register access
Read/Write
KEY: Register Write protection 
This field must be written twice, first with key value 0x55, then 0xAA, for a write operation to have an effect.
FCD: BOD Fuse calibration done 
Set to 1 when CTRL, HYST and LEVEL fields has been updated by the Flash fuses after power-on reset or Flash fuses update
If one, the CTRL, HYST and LEVEL values will not be updated again by Flash fuses 
Can be cleared to allow subsequent overwriting of the value by Flash fuses
CTRL: BOD Control 
0: BOD is off 
1: BOD is enabled and can reset the chip 
2: BOD is enabled and but cannot reset the chip. Only interrupt will be sent to interrupt controller, if enabled in the IMR register.
3: BOD is off
HYST: BOD Hysteresis
0: No hysteresis
1: Hysteresis On
LEVEL: BOD Level 
This field sets the triggering threshold of the BOD. See Electrical Characteristics for actual voltage levels.
Note that any change to the LEVEL field of the BOD register should be done with the BOD deactivated to avoid spurious reset
or interrupt.
31
30
29
28
27
26
25
24
KEY
23
22
21
20
19
18
17
16
-
-
-
-
-
-
-
FCD
15
14
13
12
11
10
9
8
-
-
-
-
-
-
CTRL
7
6
5
4
3
2
1
0
-
HYST
LEVEL
32058K
AVR32-01/12