Техническая Спецификация для STMicroelectronics 12 V, 150 mA non-isolated buck converter using VIPer™ Plus - VIPER06XS STEVAL-ISA115V1 STEVAL-ISA115V1

Модели
STEVAL-ISA115V1
Скачать
Страница из 29
Functional check
AN4260
14/29
DocID024275 Rev 2
6 Functional 
check
6.1 Startup
The startup phase at maximum load is shown in 
 at both nominal 
input voltages (115 V
AC
 and 230 V
AC
). 
6.2 Overload 
protection
In case of overload or short-circuit (see 
), the drain current reaches the I
DLIM
 value 
(or the one set by the user through the RLIM resistor). In every cycle where this condition is 
met, a counter is incremented; if it is maintained continuously for the time t
OVL
 (50 msec 
typical, internally set) the overload protection is tripped, the power section is turned off and 
the converter is disabled for a t
RESTART
 time (1 sec typical). After this time has elapsed, the 
IC resumes switching and, if the short is still present, the protection occurs indefinitely in the 
same way (
). This ensures restart attempts of the converter with low repetition 
rate, so that it works safely with extremely low power throughput and avoids the IC 
overheating in case of repeated overload events.
Figure 19. Startup at V
IN 
= 115 V
AC
, full load
Figure 20. Startup at V
IN 
= 115 V
AC
, full load, 
zoom
         
         
Figure 21. Startup at V
IN 
= 230 V
AC
, full load
Figure 22. Startup at V
IN 
= 230 V
AC
, full load, 
zoom
         
         
I_L2
AM16645v1
AM16646v1
I_L2
AM16647v1
AM16648v1