Техническая Спецификация для Panasonic AKT4111100J Temperature Controller KT4 AKT4111100J

Модели
AKT4111100J
Скачать
Страница из 11
 
KT(AKT4,7,8,9)
 
7
 
Input Type Selection
Pin Layout
Alarm (A1/A2) Behavior
Alarm Off
Max Alarm Operation 
Min Alarm Operation
Max/Min Alarm Operation
Max/Min Range Alarm Operation
Absolute Max Alarm Operation
Absolute Min Alarm Operation
Max Alarm Operation w/Standby 
Min Alarm Operation w/Standby
Max/Min Alarm Operation w/Standby
AC Power
AC Power
CT (Current Transformer) Input
Relay Connection 
Output
Thermocouple
Event output
Alarm 1 output
Resistance 
Temperature 
Detector
Direct Current, 
DC Voltage
Contact Voltage 
Output
DC Output
CT (Current 
Transformer)
to
DC Power
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
to
Press          for about 3 seconds while holding down 
         and          .
[Auxiliary Function Setup Mode 2]
Return to PV/SV Display
Input Type Selection
• Make a selection using the           and           keys.
• Factory setting is [           ].
Selection
A1 Operation Selection • Make a selection using the           and           keys.
• Factory setting is [          ].
Selection
A2 Operation Selection • Make a selection using the           and           keys.
• Displayed when Alarm 2 (A2) is added.
Selection
Normal/Reverse Control Operation Selection • Make a selection using the           and           keys.
• The factory setting is [           ].
Selection
Output Status on
Input Fault Selection
• Make a selection using the           and           keys.
• Displayed when input is direct current/DC voltage, and 
output is direct current.
Selection
Selection
A1 Operation Energized/
Non-energized Selection
• Make a selection using the           and           keys.
• Not displayed when A1 Operation Selection set to [           ].
Selection
A2 Operation Energized/
Non-energized Selection
A1 Operation Gap Setting
• Make a selection using the           and           keys.
• Not displayed when A2 Operation Selection set to [           ].
• Set the value using the           and           keys.
• Not displayed when A1 Operation Selection set to [           ].
Selection
Setting
A2 Operation Gap Setting • Set the value using the           and           keys.
• Not displayed when A2 Operation Selection set to [           ].
Setting
AT Bias Setting
• Set the value using the           and           keys.
• Displayed during thermocouple input/resistance temperature detector.
Setting
OUT/OFF Key Function Selection • Make a selection using the           and           keys.
A1 Operation Delay
Timer Setting
• Set the value using the           and           keys.
• Not displayed when A1 Operation Selection set to [           ].
Setting
A2 Operation Delay
Timer Setting
• Set the value using the           and           keys.
• Not displayed when A2 Operation Selection set to [           ].
Setting
Selection
Scaling Max Setting
• Set the value using the           and           keys.
• Displayed during direct current input/DC voltage input.
Setting
Scaling Min Setting
• Set the value using the           and           keys.
• Displayed during direct current input/DC voltage input.
Setting
OUT1 Max Setting
• Set the value using the           and           keys.
• Not displayed during ON/OFF operation.
Setting
OUT1 Min Setting
• Set the value using the           and           keys.
• Not displayed during ON/OFF operation.
Setting
OUT2 Max Setting
• Set the value using the           and           keys.
• Displayed if heating/cooling control (OUT2) is added.
Setting
OUT2 Min Setting
• Set the value using the           and           keys.
• Displayed if heating/cooling control (OUT2) is added.
Setting
Overlap/
Dead Band Setting
• Set the value using the           and           keys.
• Displayed if heating/cooling control (OUT2) is added.
Setting
OUT2 ON/OFF
Operation Gap Setting
• Set the value using the           and           keys.
• Displayed if heating/cooling control (OUT2) is added.
Setting
OUT1 ON/OFF
Operation Gap Setting
• Set the value using the           and           keys.
• Displayed during ON/OFF operation.
Setting
PV Filter
Constant Setting
• Set the value using the           and           keys.
Setting
Decimal Point Location Selection • Make a selection using the           and           keys.
• Displayed during direct current input/DC voltage input.
Selection
OUT2 Operation Mode Selection • Make a selection using the           and           keys.
• Displayed if heating/cooling control (OUT2) is added.
KT_new.fm
7 y [ W Q O O Q N P O
P V œ @
j œ @
O P P
P W “